41
Scanner
®
2000 microEFM
Section 2
4. Tighten all sections of the pipe union.
5. Connect the pressure port of the turbine meter to the external pressure transducer.
6.
Remove the plug from the conduit opening in the top of the Scanner 2000 enclosure, route the cable from
the pressure transducer through the opening, and connect it to the analog input terminal of the expansion
circuit board. A wiring diagram for the analog input is provided in
. For hazardous
areas, review
Hazardous Area Installations, page 27.
7. Install the RTD assembly in the thermowell. Remove the plug from the unused conduit opening in the
top of the Scanner 2000 enclosure, route the RTD assembly cable through the conduit opening in the top
of the Scanner 2000, and connect it to the main circuit board. A wiring diagram for the RTD assembly is
. For hazardous areas, review