D-10
Appendix D
Scanner
®
2000 microEFM
Turbine 2 Configuration
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Access
Default
2100
834
T2 - Units
See
U16
R/W
102 – BBL
2101
835
T2 - Time Base
U16
R/W
3 – Day
2102
836
T2 - Sampling Period (sec)
U16
R/W
5
2103
837
T2 - Dampening Factor
U16
R/W
0
2104
838
T2 - Input Configuration
0 - TFM Low (20 mV @ <1000 Hz)
1 - TFM Med (50 mV @ <1000 Hz)
2 - TFM High (100 mV @ <1000 Hz)
3 - TFM Max (200 mV @ <1000 Hz)
4 - Pulse Input (on expansion board)
U16
R/W
1
2105
839
T2 - Override Enable
0 - Disabled
1 - Enabled
U16
R/W
0
2106
83A
T2 - Override Value
FP
R/W
0.00
2108
83C
T2 - Fail Value
FP
R/W
0.00
2110
83E
T2 - Low Frequency Cutoff
FP
R/W
5.00
2112
840
T2 - Low Flow Cutoff
FP
R/W
0.00
2114
842
T2 - Sensor Range Low
FP
R/W
0.00
2116
844
T2 - Sensor Range High
FP
R/W
0.83333333
2118
846
T2 - Units Scale Factor
FP
R/W
0.02380952
2120
848
T2 - Units Offset Factor
FP
R/W
0.00
2122
84A
T2 - Unit Description 1
LCD
R/W
—
2123
84B
T2 - Unit Description 2
LCD
R/W
—
2124
84C
T2 - Unit Description 3
LCD
R/W
—
Turbine 2 Calibration
Register
(Decimal)
Register
(Hex)
Description
Data
Type Access
Default
2130
852
T2 - Calibration Type
1
U16
R/W
1
2131
853
T2 - Linear Factor
FP
R/W
900.00
2133
855
T2 - Calibration Absolute Offset
FP
R/W
0.00
2135
857
T2 - Factor 1
FP
R/W
900.00
2137
859
T2 - Factor 2
FP
R/W
1.00
2139
85B
T2 - Factor 3
FP
R/W
1.00
2141
85D
T2 - Factor 4
FP
R/W
1.00
2143
85F
T2 - Factor 5
FP
R/W
1.00
2145
861
T2 - Factor 6
FP
R/W
1.00
2147
863
T2 - Factor 7
FP
R/W
1.00
2149
865
T2 - Factor 8
FP
R/W
1.00
2151
867
T2 - Factor 9
FP
R/W
1.00
Содержание Scanner 2000 microEFM
Страница 1: ...NUFLO Scanner 2000 microEFM Hardware User Manual Manual No 9A 30165023 Rev 10 ...
Страница 26: ...26 Section 1 Scanner 2000 microEFM ...
Страница 104: ...A 18 Appendix A Scanner 2000 microEFM ...
Страница 106: ...B 2 Appendix B Scanner 2000 microEFM ...
Страница 188: ...E 10 Appendix D Scanner 2000 microEFM ...