7. Apply the same amount of pressure to the high side of the MVT using the simulator (see the ModWorX™
Pro Software User Manual, Part No. 9A-30165025, for complete instructions). The ModWorX™ Pro
software will display a measured value.
8. Repeat steps 6 and 7 as necessary, to enter multiple calibration points, and apply the new measured values
from the ModWorX™ Pro interface.
9.
When all calibration points have been entered, click
Save Changes
to apply the new calibration settings.
To verify the differential pressure, perform the steps described in the calibration procedure above, except
instead of choosing
Calibrate
from the Change Calibration Task window, choose
Verify
. You will be
prompted to enter an applied value, and you will apply the same amount of pressure to the MVT, just as in the
calibration process. The ModWorX™ Pro software will display a measured value and a percentage of error.
When you click
Save Changes
, the measured values are written to memory for reference.
Placing the Scanner into Operation
To put the Scanner into operation;
1. Close the vent valve.
2. Open the equalizer valves.
3. Open the bypass/block valves to allow pressure to be
supplied to both sides of the MVT.
4. Close the equalizer valves.
5. Open the vent valve (optional, some users may
choose to leave the vent closed).
Industry Standard Compliance
To ensure measurement accuracy, flow runs and turbine meter runs must be installed in accordance with
industry standards.
,
reference the sections in these standards that apply
specifically to flow run and hardware installation.
,
references standards that apply to fluid properties for gas, steam, and liquid measurement.
Fluid properties used for gas measurement calculations such as compressibility factors and density are in
accordance with AGA Report No. 8. For steam measurement, algorithms are based on the IAPWS Industrial-
Formulation 1997 (IF-97) standard. For temperature-compensated liquid measurement, fluid property
calculations are based on API-2540 - 1980, Petroleum Measurement Tables.
Heating values for gas measurement are calculated in accordance with AGA Report No. 3, Part 3, Appendix F,
using the constants defined in GPA 2145.
For more information, see the ModWorX™ Pro Software User Manual, Part No. 9A-30165025.
VENT
BYPASS/
BLOCK
EQUALIZER
BYPASS/
BLOCK
EQUALIZER
Содержание Scanner 2000 microEFM
Страница 1: ...NUFLO Scanner 2000 microEFM Hardware User Manual Manual No 9A 30165023 Rev 10 ...
Страница 26: ...26 Section 1 Scanner 2000 microEFM ...
Страница 104: ...A 18 Appendix A Scanner 2000 microEFM ...
Страница 106: ...B 2 Appendix B Scanner 2000 microEFM ...
Страница 188: ...E 10 Appendix D Scanner 2000 microEFM ...
Страница 190: ...R U S S I A 603 5569 0501 ms kl c a m com ...