C-3
MC-III™ Panel Mount Flow Analyzer
Appendix C
Note
All registers cited in this document refer to the address of the register that appears in the actual Mod
-
bus
®
message. For example, register 17001 has an address of 0x4268 Hexadecimal in the message.
Note Two sets of 16-bit holding registers are provided (starting at 17001 and 8000). The “8000” set should
be used with master devices that require the holding registers to be in the range of 40000 to 49999.
System Configuration
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Access
Default
1000
03E8
Product Code
U16
RO
64
1001
03E9
Register Table Version Number
U16
RO
1
1002
03E
Firmware Version Number
(Version = register value divided by 100)
(Example: 100 = Version 1.00)
U16
RO
1003
03EB
Manufacture Date (MMYY)
U16
RO
1004
03EC
Sales Date (MMYY)
U16
RO
1005
03ED
Serial Number 1
U16
RO
1006
03EE
Serial Number 2
U16
RO
1007
03EF
Power Mode
0 = High Power
1 = Low Power
U16
R/W
1
1008
03F0
Internal System Sample Rate
Number of seconds to measure temperature
and battery voltage
U16
R/W
3600
1009
03F1
Slave Address
[1-65535, not including 252-255 or 64764]
U16
R/W
1
1010
03F2
Baud Rate
Low Power
High Power
0 - 300 5 - 9600
1 - 600 6 - 19200
2 - 1200 7 - 38400
3 - 2400 8 - 57600
4 - 4800 10 - 115200
5 - 9600
U16
R/W
5
1011
03F3
Bus Delay – mS of delay before transmitting
data
(Delay = register value multiplied by 10 mS)
U16
R/W
1
(10 ms)
1012
03F4
Bus Timeout – mS of delay before resetting
Modbus
®
(Timeout = register value multiplied by 10 mS)
U16
R/W
5
(50 mS)
1013
03F5
Contract Hour
[0-23]
U16
R/W
8
1014
03F6
Lock Code
[0001-9999]
U16
R/W
0
Содержание NUFLO MC-III
Страница 1: ...NUFLO TM MC III Panel Mount Flow Analyzer User Manual Manual No 2350326 01 Rev 02 ...
Страница 36: ...36 Section 3 MC III Panel Mount Flow Analyzer ...
Страница 66: ...66 Section 4 MC III Panel Mount Flow Analyzer Figure 4 30 4 20 mA output test screen ...
Страница 86: ...86 Section 5 MC III Panel Mount Flow Analyzer ...
Страница 100: ...B 2 Appendix B MC III Panel Mount Flow Analyzer ...
Страница 118: ...C 18 Appendix C MC III Panel Mount Flow Analyzer ...
Страница 119: ...C 19 MC III Panel Mount Flow Analyzer Appendix C ...
Страница 120: ...R U S S I A 603 5569 0501 ms kl c a m com ...