61
MC-III™ Panel Mount Flow Analyzer
Section 4
Gas Volume Correction (Supercompressibility Calculation)
Gas turbine meters are calibrated in actual cubic feet (ACF), and measure gas in actual cubic feet. In some
applications, a user may benefit from referencing gas measurements back to standard conditions by measuring
in terms of standard cubic feet (SCF). The MC-III Panel Mount makes this process quick and easy, by using
fixed average values for the flowing gas temperature and flowing gas pressure.
By default, this option is disabled.
To access this feature, check the “Enable volume correction” checkbox in the Gas Correction section of the
K-Factor screen. The “STANDARD” annunciator on the LCD will illuminate, and all other Gas Volume
Correction data fields will be activated (Figure 4.25).
Figure 4.25—Gas volume correction settings on K-Factor Entry screen
Atmospheric pressure is set at 14.73 psia by default, but can be adjusted to local conditions.
To compensate the gas measurement to standard conditions, complete the following steps:
1. Enter the atmospheric pressure.
2. Enter the base pressure and unit. The base pressure is the pressure to which the gas will be compensated
(typically, 14.73 psia).
3. Enter the base temperature and unit. The base temperature is the temperature to which the gas will be
compensated (typically, 60°F).
4. Enter the working pressure and unit. The working pressure is the user-entered pressure that represents the
average working (flowing) pressure.
5. Enter the working temperature and unit. The working temperature is the user-entered temperature that
represents the average working (flowing) temperature.
Содержание NUFLO MC-III
Страница 1: ...NUFLO TM MC III Panel Mount Flow Analyzer User Manual Manual No 2350326 01 Rev 02 ...
Страница 36: ...36 Section 3 MC III Panel Mount Flow Analyzer ...
Страница 66: ...66 Section 4 MC III Panel Mount Flow Analyzer Figure 4 30 4 20 mA output test screen ...
Страница 86: ...86 Section 5 MC III Panel Mount Flow Analyzer ...
Страница 100: ...B 2 Appendix B MC III Panel Mount Flow Analyzer ...
Страница 118: ...C 18 Appendix C MC III Panel Mount Flow Analyzer ...
Страница 119: ...C 19 MC III Panel Mount Flow Analyzer Appendix C ...
Страница 120: ...R U S S I A 603 5569 0501 ms kl c a m com ...