C-13
MC-III™ Panel Mount Flow Analyzer
Appendix C
Holding Registers (32-bit Mode)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Access
7005
1B5D
Grand Total
(in terms of configured volume units)
FP32
RO
7006
1B5E
Instantaneous Flow Rate
(in terms of configured flow rate units)
FP32
RO
7007
1B5F
Daily Total
(in terms of configured volume units)
FP32
RO
7008
1B60
Daily Run Time
(seconds)
FP32
RO
7009
1B61
Hourly Total
(in terms of configured volume units)
FP32
RO
7010
1B62
Hourly Run Time
(seconds)
FP32
RO
7011
1B63
Polling Total
(in terms of configured volume units)
FP32
RO
7012
1B64
Polling Run Time
(seconds)
FP32
RO
7013
1B65
Previous Day Total
(in terms of configured volume units)
FP32
RO
7014
1B66
Previous Day Run Time
(seconds)
FP32
RO
7015
1B67
Previous Hour Total
(in terms of configured volume units)
FP32
RO
7016
1B68
Previous Hour Run Time
(seconds)
FP32
RO
7017
1B69
Previous Polling Total
(in terms of configured volume units)
FP32
RO
7018
1B6A
Previous Polling Run Time
(seconds)
FP32
RO
7019
1B6B
Polling Index
[0-65535]
FP32
RO
7020
1B6C
Internal Temp
(°C)
FP32
RO
7021
1B6D
Supply Voltage
(VDC)
FP32
RO
7022
1B6E
Battery Voltage
(VDC)
FP32
RO
7023
1B6F
Grand Total
(base unit)
FP32
RO
7024
1B70
Instantaneous Flow Rate
(base unit)
FP32
RO
7025
1B71
Daily Total
(base unit)
FP32
RO
Содержание NUFLO MC-III
Страница 1: ...NUFLO TM MC III Panel Mount Flow Analyzer User Manual Manual No 2350326 01 Rev 02 ...
Страница 36: ...36 Section 3 MC III Panel Mount Flow Analyzer ...
Страница 66: ...66 Section 4 MC III Panel Mount Flow Analyzer Figure 4 30 4 20 mA output test screen ...
Страница 86: ...86 Section 5 MC III Panel Mount Flow Analyzer ...
Страница 100: ...B 2 Appendix B MC III Panel Mount Flow Analyzer ...
Страница 118: ...C 18 Appendix C MC III Panel Mount Flow Analyzer ...
Страница 119: ...C 19 MC III Panel Mount Flow Analyzer Appendix C ...
Страница 120: ...R U S S I A 603 5569 0501 ms kl c a m com ...