Operation
219
Output Parameter
Description
If the Status field does not contain OK, it implies that only the Status
field is valid. In such cases, the Status field provides the reason for
not being able to read the laser powers.
CalibrationType
Indicates the measurement type that is calibrated over the criteria,
such as the following (for example):
l
Specified transceiver temperature,
l
Transceiver supply voltage,
l
TX output power, and
l
RX received optical power.
The value of this parameter is Internal.
Units
Indicates the unit of measurement.
The value of this parameter is micro-watts (mW).
txPwr
Indicates the TX output power in mW.
rxPwr
Indicates the RX received optical power in mW.
rxPwrMeasType
Indicates whether the received power measurement represents an
average input optical power.
The value of this parameter is Average.
txPwr_dBm
Indicates the TX output power in dBm.
rxPwr_dBm
Indicates the RX received optical power in dBm.
5. To download the output, click the download icon located at the top left side of the Remote
Command page.
You can also execute the Show SFP Power Details command by using the device CLI. Log on to the
device and open the CLI. At the command prompt, provide the
Show SFP
value and hit Enter on your
keyboard. The command displays the output, as shown in
.