Installation
119
Figure 101:
Locking the fine elevation adjuster
You can use the alignment tube for adjustment, as described in
8. While looking for the far node through the site, rotate the fine azimuth adjuster until the alignment
is complete in the azimuth plane. One turn of the adjustment wheel is equivalent to approximately
one degree of azimuth. Lock the fine azimuth adjuster screws in place.
9. Make any remaining adjustments to the elevation and azimuth as required. Once complete, tighten
the three Nyloc screws in place to fix the elevation alignment and do the same for the two Nyloc
screws for azimuth alignment to 10 Nm (7.4 lbft) using a 13 mm spanner or socket.
Precision bracket alignment – optional telescope
1. Attach the telescope mount to the V3000 radio using the knurled screw.
2. Attach the telescope by looping the two elastic O-rings over the ears of the mount, ensuring that
the telescope is located securely in the mount.