51
/ 55
7.
HUMAN MACHINE INTERFACE
CINERGIA delivers, within the scope of the supply, a Human Machine Interface software that
communicates with the equipment using MODBUS protocol. This application is based on
Windows 7/Windows XP. The software can be installed by executing Setup.exe file in
Administrator Mode and following the instructions of the application.
The software is based in a Tab Dialog, so each tab has different uses:
-
OPERATION
-
SUPERVISION
-
ALARM
-
I, V,P CONFIGURATION
7.1.
Operation tab
A-
Information about the status of the equipment and buttons to control it:
-
Enable / Disable:
the corresponding led shows whether the equipment is
enabled or disabled.
-
Run / Ready:
the corresponding led shows whether the equipment is running or
is ready for operation.
-
Reset:
it allows the user to reset all the alarms that have occurred and that have
been previously announced.
B-
Selection of the operating mode and information about the active one:
-
Current Control / Voltage Control / Power Control
-
Parallelized Outputs / Independent Outputs