48
/ 55
ERRORS
bits
7
6
5
4
3
2
1
0
Definition
Phase
overvoltage
Undervoltage in
the DC link
Overvoltage in
the DC link
Precharge
overload
Precharge time
Drivers
EMCY
sequence
Watchdog
Overvoltage in
phase
The DC link is
discharged
The DC link is
overcharged
Overload in
Precharge State
Internal error,
the voltage in
mains is too low
Internal error
Emergency
stop or
isolation
device is
activated
Digital processor is
blocked
bits
21
18
15
12
11
10
9
8
Definition
Mains lost
PLL error
Node without
heartbeat
Transducers offset
Room
overtemperature
Heatsink
overtemperature
Phase
overcurrent
Phase undervoltage
There is no
voltage in the
grid
PLL out of
range
Internal error,
communication
between
converters is
lost
Some transducers
are not working
properly
Not used
Heatsink
overtemp
Overcurrent
in one
phase
Undervoltage in phase
bits
31..26
25
24
23
22
Definition
reserved
Shortcircuit
Overload
Isolation
detector
Open loop
The power
supply output is
shortcircuited
The power
supply is beyond
its rated limits
There is an
isolation
fault in the
power
supply
When the power supply is
in current or power mode,
the circuit is opened