INSTALLATION
ALS
600T-AD
2019.12.5 Rev 2
Mounting Fixture
2.
Mark location where mounting clips will be installed. Quantity of mounting clips = quantity
of f1. Use a mounting clip at the joint between two fixtures (for dry location only).
5.
Screw mounting clips to surface, then snap fixture into mounting clips. Install set screws if
necessary. Set screws required for downward and outward facing applications.
Set Screw
4.
If applicable, connect disconnects between fixtures. Push and twist cap to lock connector.
Note:
Shrink tube required for wet location installations.
4’
Mounting Clip
2”
2”
2’
2”
2”
3’
2”
2”
2”
2”
1’
Shrink Tube
Apply Heat
3.
Lay mounting clips and pre-drill using proper drill bit for surface and screw size.
Recommendation:
8/32 x 1” screw.
Note:
Allow 0.25” clearance for lateral expansion of assembled mounting clips.
Only install mounting clips on flat, even surfaces.
6.
Perform continuity test steps on page 10 before connecting fixture to power source.
1.
Measure area where luminaire will be installed. Use a chalk line to ensure a straight installation.