INSTALLATION

ALS

600T-AD

2019.12.5 Rev 2

ALS600T-AD-AA-SM-X

2. 

Determine number of mounting arms needed. Use a minimum of two mounting arms per

       fixture. Mount arms 6” from center of mounting plate to end of fixture.
       Refer to spacing diagram on this page for details.

3. 

Mark location where mounting arms will be installed. Screw arms to desired surface using

       proper drill bit for surface and screw size.

4. 

Snap fixture into mounting bracket and install set screws on both sides. Ensure fixture is

       secured in place, and spacing is accurate according to the spacing diagram.

Set Screw

5. 

Loosen set screw until the mounting bracket can move freely. Turn the mounting bracket

      until desired angle is achieved, then mate the locking bump with locking hole. Tighten set
      screw until mounting bracket is secured in place.       

SPACING DIAGRAMS

4’

3’8”

2’8”

6”

6”

Mounting Arms

Example:

 4’ Fixture

4’

3’8”

2’8”

6”

6”

Mounting Arms

4’

3’8”

2’8”

6”

6”

Mounting Arms

8’

Example: 

8’ Fixture (4’ + 4’)

3’

2’8”

1’8”

6”

6”

4’

3’8”

2’8”

6”

6”

Mounting Arms

4’

3’8”

2’8”

6”

6”

Mounting Arms

11’

Example: 

11’ Fixture (4’ + 4’ + 3’)

ASSEMBLED END VIEW

Add 0.93” to overall height for fixtures with louver installed

3.01”

2.00”

X” (Specify Length)

Angle Increments

Mounting Bracket

Locking Hole

Set Screw

Locking Bump

90°

75°

60°

30°

-30°

-60°

-75°

-90°

45°

15°

-15°

-45°

-105°

1. 

Measure area where luminaire will be installed. Use a chalk line to ensure a straight installation.

6. 

If applicable, connect disconnects between fixtures. Push and twist cap to lock connector.

      

Note:

 Shrink tube required for wet location installations.

Shrink Tube

Apply Heat

Содержание alumLEDs ALS600T-AD-AA-SM Series

Страница 1: ...f LED colors and whites Available in 3 Watts up to 24 Watts Per Foot product is shipped in 1 2 3 and 4 luminaires Available for outdoor rated installations INSTALLATION RECOMMENDATIONS AlumLEDs can be...

Страница 2: ...nsult factory for any malfunctions Do not attempt to repair Only use alumLEDs with specified rated voltages Do not exceed the specified voltage for any alumLEDs luminaire Do not use alumLEDs extrusion...

Страница 3: ...e or inadvertently in the wiring the current on the control bus will be less than 1 5mA As can be determined from the two items simple two level operation of the drivers can be achieved by proper usag...

Страница 4: ...ew size Recommendation 8 32 x 1 screw Note Allow 0 25 clearance for lateral expansion of assembled mounting clips Only install mounting clips on flat even surfaces 2 Mark location where mounting clips...

Страница 5: ...imum of two mounting arms per fixture Mount arms 6 from center of mounting plate to end of fixture Refer to spacing diagrams for details 3 Mark location where mounting arms will be installed Screw arm...

Страница 6: ...ing is accurate according to the spacing diagram Set Screw 5 Loosen set screw until the mounting bracket can move freely Turn the mounting bracket until desired angle is achieved then mate the locking...

Страница 7: ...make changes or withdraw specifications without prior notice Page 7 of 11 INSTALLATION ALS600T AD 2019 12 5 Rev 2 Accessories ALS600T AD LVR 1 Place louvers onto top of extrusion ensuring internal opt...

Страница 8: ...n 1 Slightly unscrew Pivot Lock Knobs on both ends of fixture until Pivot Lock Bar and Upper Extrusion move freely Do not remove Pivot Lock Knob 2 Adjust as needed Use Angle Finder Markings on end cap...

Страница 9: ...en snap fixture into mounting clips Install set screws if necessary Set screws required for downward and outward facing applications Set Screw 4 If applicable connect disconnects between fixtures Push...

Страница 10: ...obe to a wire and the black probe to each other wire Repeat for each wire If a conductive path is formed between any of the wires the multimeter will beep flash or read 0 ohms Troubleshoot to identify...

Страница 11: ...carbonate 6 18AWG stranded 105 C stripped 3 8 tinned 60Hz PRODUCT FEATURES The Surge Series are 3 leaded devices that protect Line Ground Line Neutral and Neutral Ground in accordance with IEEE ANSI C...

Отзывы: