INSTALLATION

ALS

600T-AD

2019.12.5 Rev 2

Surge Protector

1.0” 1.52”

.26”

.26”

.25”

ø 1.14”

.41”

2.91”

1.91”

1.16”

.09”

.58”

LED Lighting

0-10V Dimming

ALS-SP

TRA-E Power Source

120V-277V

V+

Hot

Ground (Green)

V-

Neutral

Hot (Black)

V-

Neutral (White)

Ground (Green)

V+

LED Lighting

TRA Power Source

120V-24VDC

Forward Phase 
Dimming

ALS-SP

Line

V- (Blue)
V+ (Red)

Hot (Black)

Neutral (White)

Ground (Green)

Black (Hot)

Neutral (White)

Ground (Green)

LED Lighting

Forward Phase 
Dimming

ALS-SP

Line

V- (Blue)
V+ (Red)

277V (Orange)

Neutral (White)

Ground (Green)

Hot (Black)

Neutral (White)

Ground (Green)

TRA Power Source

277V-24VDC

SURGE PROTECTOR SPECIFICATIONS

MODEL

INPUT VOLTAGE

SURGE PROTECTION LEVEL

MOUNTING

ENCLOSURE MATERIAL

INPUT LEADS

INPUT 

FREQUENCY

ALS-SP

120V - 277V

10kV, 10kA, ANSI C62.41 Category C

SnapLOCK / Footed

Polycarbonate

6”, 18AWG stranded, 105°C stripped, 3/8” tinned

60Hz

PRODUCT FEATURES

The Surge Series are 3-leaded devices that protect Line-Ground, Line-Neutral, and Neutral-
Ground in accordance with IEEE / ANSI C62.41.2 guidelines. Protects against surges according 
to IE EE C62.41.2 C High (10kA and 10kV). Surge current rating = 10,000 Amps using industry 
standard 8/20 µSec wave. Surge Location Rated Category C3. UL Recognized Component in the 
United States and Canada (UL1449). Type 4 Surge Protection Device. High temperature, flame 
retardant plastic enclosure, 85°C maximum surface temperature rating. Thermally Protected 
Transient Over-voltage Circuit.

PRODUCT SPECIFICATIONS

The Surge series of products are designed to be used in conjunction with LED Drivers and 
fixtures to provide an additional level of protection against powerline disturbances in industrial, 
commercial and residential applications where surge protection to IEEE C62.41.2 is required.

0-10V WIRING DIAGRAM (10V Dimming)

120V WIRING DIAGRAM (Forward Phase Dimming)

277V WIRING DIAGRAM (Forward Phase Dimming)

CASE DIMENSIONS

Note:

 Wire colors vary based on model. See individual TRA-E submittal for more information, or refer to

           wire callouts on transformer labeling. Always confirm wire colors before connecting to power source.

Содержание alumLEDs ALS600T-AD-AA-SM Series

Страница 1: ...f LED colors and whites Available in 3 Watts up to 24 Watts Per Foot product is shipped in 1 2 3 and 4 luminaires Available for outdoor rated installations INSTALLATION RECOMMENDATIONS AlumLEDs can be...

Страница 2: ...nsult factory for any malfunctions Do not attempt to repair Only use alumLEDs with specified rated voltages Do not exceed the specified voltage for any alumLEDs luminaire Do not use alumLEDs extrusion...

Страница 3: ...e or inadvertently in the wiring the current on the control bus will be less than 1 5mA As can be determined from the two items simple two level operation of the drivers can be achieved by proper usag...

Страница 4: ...ew size Recommendation 8 32 x 1 screw Note Allow 0 25 clearance for lateral expansion of assembled mounting clips Only install mounting clips on flat even surfaces 2 Mark location where mounting clips...

Страница 5: ...imum of two mounting arms per fixture Mount arms 6 from center of mounting plate to end of fixture Refer to spacing diagrams for details 3 Mark location where mounting arms will be installed Screw arm...

Страница 6: ...ing is accurate according to the spacing diagram Set Screw 5 Loosen set screw until the mounting bracket can move freely Turn the mounting bracket until desired angle is achieved then mate the locking...

Страница 7: ...make changes or withdraw specifications without prior notice Page 7 of 11 INSTALLATION ALS600T AD 2019 12 5 Rev 2 Accessories ALS600T AD LVR 1 Place louvers onto top of extrusion ensuring internal opt...

Страница 8: ...n 1 Slightly unscrew Pivot Lock Knobs on both ends of fixture until Pivot Lock Bar and Upper Extrusion move freely Do not remove Pivot Lock Knob 2 Adjust as needed Use Angle Finder Markings on end cap...

Страница 9: ...en snap fixture into mounting clips Install set screws if necessary Set screws required for downward and outward facing applications Set Screw 4 If applicable connect disconnects between fixtures Push...

Страница 10: ...obe to a wire and the black probe to each other wire Repeat for each wire If a conductive path is formed between any of the wires the multimeter will beep flash or read 0 ohms Troubleshoot to identify...

Страница 11: ...carbonate 6 18AWG stranded 105 C stripped 3 8 tinned 60Hz PRODUCT FEATURES The Surge Series are 3 leaded devices that protect Line Ground Line Neutral and Neutral Ground in accordance with IEEE ANSI C...

Отзывы: