background image

2

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

1

22

3

1

Front panel

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

1) LED indicators:

2) LCD display:

green LED on: 

mains LED

fixed red LED:  

disinfection in progress, acquisition of full 
scale and thermal shock in progress:  
potentially hazardous condition

red flashing LED: 

alarm condition

Display when switched on

When the device is switched on, the green LED lights up and the 

following screen appears on the display.

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

It is necessary to check the presence of the battery in the appropriate 

seat. Before carrying out this check, remove electric supply, check that 

the battery is properly fitted, reconnect the electric supply, and confirm 

pressing the knob, when the previous screen reappears. When the 

device is switched on again, the red LED will stop flashing.

Important: If the battery is not inserted or it is low, the 

appliance will still work, but in the event of a power failure 

the time will not be saved. 

It is recommended to refer to the alarm section in 

this manual. (For correct battery installation, see the 

"Installation and commissioning manual", supplied in the 

package).

When the battery checks are completed, the device time and date 

configuration starts. 

Use the knob to change the values and press to confirm.

- Enter the time turning the knob

- Press the knob to confirm the time set

- Enter the minutes turning the knob

- Press the knob to confirm the minutes set

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

1)   Warning signal

2)   "Installer menu" block

3)   SET temperature not reached

4)   Maintenance

5)   Manual

6)   Disinfection/thermal shock not performed

7)   Motor in operation

8)   No mains voltage

9)   Functional parameters

10)  Outlets and inlets

11)  Motor movement

12)  Days of the week/time bands 

13)  Clock

3) Control knob

Turning the knob scrolls through the menus.

Pressing the knob confirms the selected values (depending on 

the pressing time it is possible to access several work screens. 

 

See page 9).

file originale

1
2
3
4
5

6

7
8
9

10

11

12

13

After about 2 seconds, the battery control screen will appear on the 

display.

Date and time configuration

Содержание LEGIOMIX 6000 series

Страница 1: ...and default values Display menu Programming Menu Installer Menu Alarm management General diaphragm 2 3 6 8 7 10 11 14 PROGRAMMING MANUAL Copyright 2018 Caleffi H0004567 01 www caleffi com Disinfection...

Страница 2: ...ved It is recommended to refer to the alarm section in this manual For correct battery installation see the Installation and commissioning manual supplied in the package When the battery checks are co...

Страница 3: ...evice does not perform the disinfection Operating status During the operation of the device the following work states can be displayed 1 Reached setpoint 2 Adjustment in progress 3 Disinfection in pro...

Страница 4: ...rts are in orange b Disinfection in progress with control on return probe T2 see table on page 5 In this mode the device performs thermal disinfection which consists in raising the mixed water tempera...

Страница 5: ...be T1 d2 Disinfection performed at the minimum disinfection temperature diS C Disinfection check performed on probe T1 Disinfection type with recirculation probe T2 enabled Disinfection Code Descripti...

Страница 6: ...set tHi diS or with the manual opening of the contact Manual activation through button Automatic end The disinfection status ends as soon as the minimum disinfection time tmin diS is exceeded or withi...

Страница 7: ...Reset alarms control Additionally the zero acquisition mode is activated whenever an electric supply failure occurs for at least 60 minutes and at the outlet from any disinfection thermal shock It is...

Страница 8: ...om 00 to 99 17 14 Time format selection 12H 24H 24H 15 Hours minutes setting 0 23 hours 0 59 minutes 00 00 16 Daylight saving time setting YES on NO off On 17 Disinfection program change d1 d2 d2 18 T...

Страница 9: ...hatever status the appliance is in it is always possible to navigate around the various menus to read and change the various settings The general menu structure is as follows Display menu Press the kn...

Страница 10: ...or the day set is displayed the segment below the number indicates its activation Maximum time within which it is possible to perform the disinfection Maximum flow temperature limit it is a system pro...

Страница 11: ...uring which the temperature must remain above the set temperature for the thermal shock Setting the maximum time available within which it is possible to perform the thermal shock RESET Control to res...

Страница 12: ...x time bands that can be set for recirculation OUT2 activation 1 02 00 and 05 59 4 14 00 and 17 59 2 06 00 and 09 59 5 18 00 and 21 59 3 10 00 and 13 59 6 22 00 and 01 59 Installer Menu password chang...

Страница 13: ...of the valve Perform with closed shut off valves The number of times the error has occurred appears in the top right of the screen To delete the alarms from the sub menu use the Reset Alarms Installe...

Страница 14: ...F RESETTING BLOCKING ALARM The device resumes its operation when the probe T1 returns to the set value Alarm management To make it easier to resolve any functional faults that occur after installation...

Страница 15: ...er mixing status the first successful disinfection clears the alarm condition but records it in the log of the last failed disinfections the display shows the symbol Manual YES it is also recorded in...

Страница 16: ...failure for more than 60 minutes NON BLOCKING ALARM When the electric supply is restored it resumes normal operation after performing the zero acquisition AL08 FAULTY FLOW PROBE SELF RESETTING BLOCKIN...

Страница 17: ...NC Closed OUT2 Closed OUT3 Open The device can only perform the water mixing while maintaining the alarm active YES PROBE T2 NOT CONNECTED OR DAMAGED Check that the probe is present and correctly con...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Отзывы: