background image

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

AVOIDING THE RISK TO CHILDREN

DANGER:

RISK OF CHILD DROWNING.

Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot

use a spa unless they are supervised at all times.

WARNING:

• To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
• To reduce the risk of injury, lower water temperatures are recommended for young children. Children are especially sensitive to hot water.

DO:

• Make sure you always lock the child resistant locks after using the spa for your children’s safety. Every Caldera

®

spa is equipped with a locking cover that meets

the ASTM F1346-91 Standard for Safety Covers.

• Test the water temperature with your hand before allowing your child to enter the spa to be sure that it’s comfortable. Children are especially sensitive to hot

water.

• Remind children that wet surfaces can be very slippery. Make sure that the children are careful when entering or exiting the spa.

DON’T:

• Allow children to climb onto the spa cover.
• Allow children to have unsupervised access to the spa.

AVOIDING THE RISK OF ELECTROCUTION

Risk of electrocution

• Connect only to a grounded source.
• Do not bury the power cord. A buried power cord may result in death or serious personal injury due to electrocution if direct burial-type cable is not used, or if

improper digging occurs.

• A ground terminal (pressure wire connector) is provided on the control box inside the unit to permit connection of a minimum No. 10 AWG solid copper bonding

conductor between this point and any metal equipment, metal water pipe, metal enclosures of electrical equipment, or conduit within five feet (1.5 m) of the unit
as needed to comply with local requirements.

WARNING:

• To reduce the risk of electrical shock, replace a damaged cord immediately. Failure to do so may result in death or serious personal injury due to electrocution.
• Your spa is provided with a Ground Fault Circuit Interrupter for user and equipment protection. To ensure proper operation of this important safety device, test

according to the following instructions per electrical configuration.

Cord-Connected 115 volt, 15 and 20 amp models:

The GFCI is located at the end of the power cord. Before each use, with the unit operating, push the TEST

button. The unit should stop operating and the GFCI power indicator will go out. Wait 30 seconds and then reset the GFCI by pushing the RESET button. The
GFCI power indicator will turn on, restoring power to the spa. If the interrupter does not perform in this manner, there may be an electrical malfunction and with
it, the possibility of an electric shock. Disconnect the power until the problem has been corrected.

230 volt, permanently installed or converted models:

• A ground terminal is provided on the terminal block located inside the control box. To reduce the risk of electric shock, connect this terminal to the grounding

terminal of your electrical service or supply panel with a continuous green, insulated copper wire. The wire must be equivalent in size to the circuit conductors
supplying the equipment. In addition, a bonding terminal (pressure wire connector) is provided on the outside of the control box for bonding to local ground
points. To reduce the risk of electric shock, this connector should be bonded with a No. 10 AWG solid copper wire to any metal ladders, water pipes, or other
metal within 5 feet (1.5 m) of the spa to comply with local requirements. The means of disconnection must be readily accessible, but must be installed at least 5
feet (1.5 m) from the spa.

• Your spa is provided with a suitably rated circuit breaker to open all ungrounded supply conductors.
• Your spa uses ground fault circuit interrupters in the electrical subpanel. Before each use of the spa and with the unit operating, push the Test button on each

breaker. The switch should click over to the “Trip” position. Wait 30 seconds and reset each GFCI breaker by switching it completely off and then completely on.
The switch should then stay on. If either of the interrupters does not perform in this manner, it is an indication of an electrical malfunction and the possibility of
an electric shock. Disconnect the power until the fault has been identified and corrected.

SAFETY INFORMATION

1

Содержание Olympia

Страница 1: ...OWNER S MANUAL H i g h l a n d S e r i e s Olympia Cascade CumberlandTM...

Страница 2: ...____________________________ SPA MODEL SERIAL NUMBER ______________________________ COVER SERIAL NUMBER ____________________________________ In most cities and counties permits will be required for th...

Страница 3: ...l Information 11 Methods for Testing the Spa Water 11 The Watkins Spa Water Maintenance Program 12 Chlorine sodium dichlor 14 Monarch Ozone System Optional 16 PureWater Ozone System Optional 16 Common...

Страница 4: ...protection To ensure proper operation of this important safety device test according to the following instructions per electrical configuration Cord Connected 115 volt 15 and 20 amp models The GFCI is...

Страница 5: ...pa if the suction fittings are broken or missing People with infectious diseases should not use the spa Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving c...

Страница 6: ...n additional SAFETY SIGNS contact your Caldera dealer and request Part 003021 IMPORTANT SPA INSTRUCTIONS The following contains important spa information and we strongly encourage you to read and appl...

Страница 7: ...l requirements if you place your spa indoors Water will accumulate around the spa so flooring materials must provide a good grip when wet Proper drainage is essential to prevent a build up of water ar...

Страница 8: ...odule showing where the connections are to be made ELECTRICAL REQUIREMENTS AND PRECAUTIONS Your Caldera spa has been carefully designed to give you maximum safety against electrical shock Connecting t...

Страница 9: ...service to the subpanel terminal L1 3 Connect the 8 AWG RED L2 wire from the main electrical service to the subpanel terminal L2 4 Connect the 10 AWG GREEN wire from the Neutral Ground Bar on the main...

Страница 10: ...r compartment with the jet pump on high speed for at least ten minutes OPERATION NOTE Adjusting the Total Alkalinity as the first step is important as out of balance TA will affect your ability to adj...

Страница 11: ...compartment 4 Temperature sensor 5 Spa light OLYMPIA MODEL SHOWN FEATURES AND LOCATIONS WILL VARY IN OTHER MODELS 3 1 2 4 5 6 9 6 Drain suction fitting 7 Outlet for optional ozone 8 Magna Jets 9 Euro...

Страница 12: ...et button changes the jet pump functions depending on the number of presses Oympia Spa only 1st press Two speed jet pump runs on low speed 2nd press Two speed jet pump runs on high speed 3rd press One...

Страница 13: ...ed the FILTER LED will blink Once the jet pump has been shut off a ten minute tranquil mode begins FILTER LED will be blinking during tranquil mode before the filter cycle will resume The blinking fil...

Страница 14: ...ly and follow directions precisely Though chemicals protect you and your spa when used correctly they can be hazardous in concentrated form Always observe the following guidelines Allow only a respons...

Страница 15: ...evel for your spa is 150 200 ppm B Calcium Hardness is a measure of the total amount of dissolved calcium in the water Calcium helps control the corrosive nature of the spa s water That s why calcium...

Страница 16: ...water It is important to follow the recommended application and maintenance programs outlined for each product s use If the spa is being used over an extended period or time such as a whole afternoon...

Страница 17: ...ontaminants in the water may coat the silver cartridge s ceramic beads blocking the silver ions release into the water When this occurs there will be no residual of silver ions present in the water el...

Страница 18: ...e amount of time a user spends in the spa Sanitizer Needed is the amount of Free Available Chlorine FAC needed to accommodate the number of users and their combined usage time For example two spa user...

Страница 19: ...Watkins Manufacturing Corporation recommends that a chemical maintenance program based on recognized and documented industry standards still be followed when using an ozone purification system to ass...

Страница 20: ...or or seat of the spa shell These pieces of sanitizer will chemically burn blister the spa shell Although your spa shell is specifically designed to resist the effects of spa chemicals no spa surface...

Страница 21: ...is caused by mineral content combined with high pH Additionally scale forms more readily at higher water temperatures Shock Treatment Also known as super chlorination when chlorine is used Shock treat...

Страница 22: ...the clear lens to create the desired ambiance SPA LIGHT BULB REPLACEMENT To replace the spa light bulb disconnect power to the spa 1 Remove equipment compartment door 2 Locate the rear of the spa lig...

Страница 23: ...lons of water or baking soda sodium bicarbonate scrub the vinyl top in a circular motion Do not let the vinyl dry with a soap film on it before it can be rinsed clean 4 Scrub the cover s perimeter and...

Страница 24: ...not covered by warranty WINTERIZING YOUR SPA If the spa is located where freezing temperatures occur and you do not intend to use your spa for an extended period follow steps 1 through 7 outlined in D...

Страница 25: ...surface material can withstand this kind of abuse damage to components or spa surface caused by improper water chemistry maintenance and damage to the spa surface caused by leaving the spa uncovered w...

Страница 26: ...clogged filter If tripping continues call for service Check for clogged filter The pressure switch will reset when the flow of water through the heater has been restored Call for service if the pressu...

Страница 27: ......

Страница 28: ...amp Dedicated GFCI protected cord or 230 volt 50 amp Single phase GFCI circuit 7 0 x 7 0 Olympia 36 75 square feet 4 000 360 gallons 706 lbs 4 744 lbs 100 lbs per square foot 230 volt 30 50 amp Singl...