background image

WARNING: 

High sanitizer levels can cause discomfort to the user’s eyes, lungs and skin. Always allow the sanitizer level to fall to the recommended range before

using the spa.

IMPORTANT “SUPER CHLORINATION/NON-CHLORINE SHOCK TREATMENT” NOTE:

After administering a super chlorination treatment or non-chlorine shock to

your spa, leave the cover open for a minimum of 20 minutes to allow the oxidizer gas to vent. A high concentration of trapped oxidizer gas which may exist as a result of
the shock treatment (not daily sanitation) may eventually cause discoloration or vinyl degradation to the bottom of the cover. This type of damage is considered chemical
abuse and is not covered under the terms of the limited warranty.

THE WATKINS

®

SPA WATER MAINTENANCE PROGRAM

Each step in your water maintenance program is dependent on the completion of the previous steps. Omitting a step or failing to reach the recommended range may
cause an imbalance in your water’s chemistry. Unbalanced water chemistry can damage the spa and its components, as well as cause discomfort for the user.

BALANCING THE TOTAL ALKALINITY (TA)

A. The recommended Total Alkalinity (TA) for your spa water is 125-150 ppm.

B. Total Alkalinity is a measure of the total levels of carbonates, bicarbonates, hydroxides, and other alkaline substances in the water. TA is referred to as the water’s

“pH buffer”. In other words, it’s a measure of the ability of the water to resist changes in pH level.

C. If the TA is too low, the pH level will fluctuate widely from high to low. Fluctuations in pH can cause corrosion or scaling of the spa components. 

Low TA can be

corrected by adding sodium hydrogen carbonate (pH/Alkalinity Up).

D. If the Total Alkalinity is too high, the pH level will tend to be high and may be difficult to bring down. 

It can be lowered by using sodium bisulfate  (pH/Alkalinity

Down).

E. Once the TA is balanced, it normally remains stable, although the addition of more water with a high or low alkalinity will raise or lower the TA reading of the water.

F.

When the Total Alkalinity is within the recommended range, proceed to the next step.

BALANCING THE CALCIUM HARDNESS (CH)

A. The recommended Calcium Hardness (CH) level for your spa is 150-200 ppm.

B. Calcium Hardness is a measure of the total amount of dissolved calcium in the water. Calcium helps control the corrosive nature of the spa’s water. That’s why

calcium-low water (commonly known as “soft” water) is not recommended. It is very corrosive to the equipment, and can cause staining of the spa shell. 

C. If the CH is too high (commonly known as “hard water”), formation of scale on the spa’s shell surface and equipment can result. 

CH can be decreased by

dilution–a mixture of 75% hard and 25% soft water will usually yield a reading within the correct range.

If soft water is not available or practical for you, a

stain and scale inhibitor should be added to the spa water, according to label instructions.

D. If the CH is too low add CH Increaser.

E. Once the CH is balanced, it normally remains stable, although the addition of more water with a high or low calcium content will raise or lower the CH reading of the water.

F.

When the Calcium Hardness is within the recommended range, proceed to the next step.

BALANCING THE pH

A. The recommended pH level for your spa water is 7.4-7.6.

B. The pH level is the measure of acidity and alkalinity. Values above 7 are alkaline; those below 7 are acidic.

Maintaining the proper pH level is extremely important for:

• Optimizing the effectiveness of the sanitizer.
• Maintaining water that is comfortable for the user.
• Preventing equipment deterioration.

C. If the spa water’s pH level is too low, the following may result:

• The sanitizer will dissipate rapidly.
• The water may become irritating to spa users.
• The spa’s equipment may corrode.

If the pH is too low, it can be increased by adding sodium hydrogen (pH/Alkalinity Up) carbonate to the spa
water.

D. If the pH level is too high, the following may result:

• The sanitizer is less effective.
• Scale will form on the spa shell surface and the equipment.
• The water may become cloudy.
• The filter cartridge pores may become obstructed.

If the pH is too high, it can be decreased by adding sodium bisulfate (pH/Alkalinity Down) to the spa water. 

NOTE:

After adding sodium hydrogen carbonate, or sodium bisulfate, 

wait two hours

before testing the water for pH. Measurements taken too soon may not be

accurate.

WATER QUALITY AND MAINTENANCE

12

ALKALINE

SPA

WATER

(SCALING

ZONE)

ADD pH

DECREASER

TO LOWER

pH

ACIDIC

SPA

WATER

(CORROSIVE

ZONE)

ADD pH

INCREASER

TO RAISE

pH

COMFORT

ZONE

IDEAL

Содержание Olympia

Страница 1: ...OWNER S MANUAL H i g h l a n d S e r i e s Olympia Cascade CumberlandTM...

Страница 2: ...____________________________ SPA MODEL SERIAL NUMBER ______________________________ COVER SERIAL NUMBER ____________________________________ In most cities and counties permits will be required for th...

Страница 3: ...l Information 11 Methods for Testing the Spa Water 11 The Watkins Spa Water Maintenance Program 12 Chlorine sodium dichlor 14 Monarch Ozone System Optional 16 PureWater Ozone System Optional 16 Common...

Страница 4: ...protection To ensure proper operation of this important safety device test according to the following instructions per electrical configuration Cord Connected 115 volt 15 and 20 amp models The GFCI is...

Страница 5: ...pa if the suction fittings are broken or missing People with infectious diseases should not use the spa Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving c...

Страница 6: ...n additional SAFETY SIGNS contact your Caldera dealer and request Part 003021 IMPORTANT SPA INSTRUCTIONS The following contains important spa information and we strongly encourage you to read and appl...

Страница 7: ...l requirements if you place your spa indoors Water will accumulate around the spa so flooring materials must provide a good grip when wet Proper drainage is essential to prevent a build up of water ar...

Страница 8: ...odule showing where the connections are to be made ELECTRICAL REQUIREMENTS AND PRECAUTIONS Your Caldera spa has been carefully designed to give you maximum safety against electrical shock Connecting t...

Страница 9: ...service to the subpanel terminal L1 3 Connect the 8 AWG RED L2 wire from the main electrical service to the subpanel terminal L2 4 Connect the 10 AWG GREEN wire from the Neutral Ground Bar on the main...

Страница 10: ...r compartment with the jet pump on high speed for at least ten minutes OPERATION NOTE Adjusting the Total Alkalinity as the first step is important as out of balance TA will affect your ability to adj...

Страница 11: ...compartment 4 Temperature sensor 5 Spa light OLYMPIA MODEL SHOWN FEATURES AND LOCATIONS WILL VARY IN OTHER MODELS 3 1 2 4 5 6 9 6 Drain suction fitting 7 Outlet for optional ozone 8 Magna Jets 9 Euro...

Страница 12: ...et button changes the jet pump functions depending on the number of presses Oympia Spa only 1st press Two speed jet pump runs on low speed 2nd press Two speed jet pump runs on high speed 3rd press One...

Страница 13: ...ed the FILTER LED will blink Once the jet pump has been shut off a ten minute tranquil mode begins FILTER LED will be blinking during tranquil mode before the filter cycle will resume The blinking fil...

Страница 14: ...ly and follow directions precisely Though chemicals protect you and your spa when used correctly they can be hazardous in concentrated form Always observe the following guidelines Allow only a respons...

Страница 15: ...evel for your spa is 150 200 ppm B Calcium Hardness is a measure of the total amount of dissolved calcium in the water Calcium helps control the corrosive nature of the spa s water That s why calcium...

Страница 16: ...water It is important to follow the recommended application and maintenance programs outlined for each product s use If the spa is being used over an extended period or time such as a whole afternoon...

Страница 17: ...ontaminants in the water may coat the silver cartridge s ceramic beads blocking the silver ions release into the water When this occurs there will be no residual of silver ions present in the water el...

Страница 18: ...e amount of time a user spends in the spa Sanitizer Needed is the amount of Free Available Chlorine FAC needed to accommodate the number of users and their combined usage time For example two spa user...

Страница 19: ...Watkins Manufacturing Corporation recommends that a chemical maintenance program based on recognized and documented industry standards still be followed when using an ozone purification system to ass...

Страница 20: ...or or seat of the spa shell These pieces of sanitizer will chemically burn blister the spa shell Although your spa shell is specifically designed to resist the effects of spa chemicals no spa surface...

Страница 21: ...is caused by mineral content combined with high pH Additionally scale forms more readily at higher water temperatures Shock Treatment Also known as super chlorination when chlorine is used Shock treat...

Страница 22: ...the clear lens to create the desired ambiance SPA LIGHT BULB REPLACEMENT To replace the spa light bulb disconnect power to the spa 1 Remove equipment compartment door 2 Locate the rear of the spa lig...

Страница 23: ...lons of water or baking soda sodium bicarbonate scrub the vinyl top in a circular motion Do not let the vinyl dry with a soap film on it before it can be rinsed clean 4 Scrub the cover s perimeter and...

Страница 24: ...not covered by warranty WINTERIZING YOUR SPA If the spa is located where freezing temperatures occur and you do not intend to use your spa for an extended period follow steps 1 through 7 outlined in D...

Страница 25: ...surface material can withstand this kind of abuse damage to components or spa surface caused by improper water chemistry maintenance and damage to the spa surface caused by leaving the spa uncovered w...

Страница 26: ...clogged filter If tripping continues call for service Check for clogged filter The pressure switch will reset when the flow of water through the heater has been restored Call for service if the pressu...

Страница 27: ......

Страница 28: ...amp Dedicated GFCI protected cord or 230 volt 50 amp Single phase GFCI circuit 7 0 x 7 0 Olympia 36 75 square feet 4 000 360 gallons 706 lbs 4 744 lbs 100 lbs per square foot 230 volt 30 50 amp Singl...

Отзывы: