10
OPERATING INSTRUCTIONS
FILTER CYCLES
Your spa will automatically turn the filter cycle on twice each day. When the spa is first powered up the automatic filter cycle will wait 12 hours before starting. A six
hour filter cycle using the low speed of the jet pump is the programmed default filter cycle time. The filter cycle occurs twice a day (every 12 hours).
NOTE:
The optional Monarch
TM
and PureWater
TM
ozone systems only work during the filter cycles.
To modify the length of the filter cycle:
A.
Press and hold the Light button for approximately five seconds until the display shows “xx” where xx is a number from 0-12. This is the length of the filter time.
B.
Using the Temp Plus (+) or the Temp Minus (–) button, adjust the value as desired.
C. Pressing the LIGHT button again confirms the setting and starts a cycle immediately.
D. If the LIGHT button is not pressed again, the new filter time is stored, but the cycle is started at the next scheduled time.
The filter cycle will activate the jet pump on low speed for the entire cycle. When activated, the filter cycle LED on the display is turned on. If the temperature exceeds
the set point by three degrees F for more than three hours, the system will cancel the FILTER cycle and the filter LED will blink for the remaining filter cycle time. Should
the temperature cool down to two degrees F above the set point before the end of the cycle, the cycle will resume for the rest of the time. Should you use the spa
during the filter cycle by placing the jet pump on high speed, the FILTER LED will blink. Once the jet pump has been shut off, a ten minute tranquil mode begins (FILTER
LED will be blinking during tranquil mode) before the filter cycle will resume. The blinking filter LED indicates that the filter cycle timer is still counting, but the cycle has
been temporarily interrupted.
NOTE
: The interrupted time of a filter cycle is not extended after the filter cycle resumes. Power interruptions of the spa will reset the filter cycle to the default six hour
cycle time and begin 12 hours after spa regains power.
AIR CONTROL
The Air Control(s) located next to your spa-side control panel allows you to change the power of the jets by regulating the amount of air that is mixed with the water
coming out of the jets.
HYDRO JETS
Magna
TM
Jets – The larger jets in your spa allow you to re-direct the jet stream by changing the position of the nozzle.
You can also regulate the force of the massage by rotating the jet face clockwise to reduce the force or counter-clockwise to increase the force. Notice that turning off
the flow to some jets increases the flow to the other jets. To avoid damage to your spa’s plumbing and components,
do not turn off more than half of these jets at
the same time
.
MagnaSsage
TM
rotating nozzles are available from your dealer, to replace the directional adjustable nozzles in the Magna Jets.
Euro Directional Jets – The small euro jets deliver a direct, precision massage. You may also purchase Euro-Pulse
TM
assemblies from your dealer that would replace the
Euro directional jets to provide a pulsating, rotary massage. This can be accomplished by simply twisting off the Euro jet face, adding the nozzle and nozzle retainer,
then reinstalling the Euro jet face.