background image

DANGER: RISK OF ELECTRICAL SHOCK

• Install spa at least 5 feet (1.5 m) from all metal surfaces. A spa may be installed within 5 feet of a metal surface if each metal surface is permanently connected

by a minimum No. 10 AWG solid copper conductor attached to the wire ground connector on the terminal box that is provided for this purpose if in accordance
with National Electrical Code ANSI/NMFPA70-1993.

• Do not permit any electrical appliances, such as a light, telephone, radio, or television within 5 feet (1.5 m) of a spa. Failure to maintain a safe distance may

result in death or serious personal injury due to electrocution if the appliance should fall into the spa.

• Install your spa in such a way that drainage is away from the electrical compartment and from all electrical components.

DO:

• Be sure your spa is connected to the power supply correctly - use a licensed electrical contractor.
• Disconnect the spa from the power supply before draining the spa or servicing the electrical components.
• Test the Ground Fault Circuit Interrupter(s) before each use.

DON’T:

• Use the spa with the equipment compartment door removed.
• Place electrical appliances within 5 feet (1.5m) of the spa.
• Use an extension cord to connect the spa to its power source. The cord may not be properly grounded and the connection is a shock hazard. An extension

cord may cause a voltage drop, which will cause overheating of the jet pump motor and motor damage.

• Attempt to open the electrical control box. There are no user serviceable parts inside.

RISKS TO AVOID

DANGER: RISK OF INJURY

• To reduce the risk of injury to persons, DO NOT remove floating weir, basket, and filter located in the filter compartment while the spa is running.
• The suction fittings in the spa are sized to match the specific water flow created by the pump. Never replace a suction fitting with one rated less than the flow

rate marked on the original suction fitting.

• There is a danger of slipping and falling. Remember that wet surfaces can be very slippery. Take care when entering or exiting the spa.
• Never operate spa if the suction fittings are broken or missing.
• People with infectious diseases should not use the spa.
• Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving components. 

Increased side effects of medication

• The use of drugs, alcohol or medication before or during spa use may lead to unconsciousness with the possibility of drowning.
• Persons using medications should consult a physician before using a spa; some medication may cause a user to become drowsy, while other medication may

affect heart rate, blood pressure, and circulation.

• Persons taking medications which induce drowsiness, such as tranquilizers, antihistamines or anticoagulants should not use the spa.

Health problems affected by spa use

• Pregnant women should consult a physician before using spa.
• Persons suffering from obesity or with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a

physician before using spa.

Unclean water

• Keep the water clean and sanitized with correct chemical care. The recommended levels for your Caldera

®

spa are:

Free Available Chlorine (FAC):

3.0-5.0 ppm

Total Alkalinity:

125-150 ppm

Water pH:

7.4-7.6

Calcium Hardness:

150-200 ppm

(Refer to Water Quality and Maintenance section for complete instructions.)

IMPORTANT: 

Turn jet pump on for a least ten minutes after adding ANY spa water chemicals into the filter compartment.

• Clean the filter cartridge monthly to remove debris and mineral buildup which may affect the performance of the hydromassage jets, limit the flow, or trip the

high-limit thermostat which will turn off the entire spa.

AVOIDING THE RISK OF HYPERTHERMIA

Prolonged immersion in hot water can result in HYPERTHERMIA, a dangerous condition which occurs when the internal temperature of the body reaches a level above
normal (98.6°F). The symptoms of hyperthermia include unawareness of impending hazard, failure to perceive heat, failure to recognize the need to exit the spa, physical
inability to exit the spa, fetal damage in pregnant women, and unconsciousness resulting in a danger of drowning. 

WARNING:

The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.

SAFETY INFORMATION

2

Содержание Olympia

Страница 1: ...OWNER S MANUAL H i g h l a n d S e r i e s Olympia Cascade CumberlandTM...

Страница 2: ...____________________________ SPA MODEL SERIAL NUMBER ______________________________ COVER SERIAL NUMBER ____________________________________ In most cities and counties permits will be required for th...

Страница 3: ...l Information 11 Methods for Testing the Spa Water 11 The Watkins Spa Water Maintenance Program 12 Chlorine sodium dichlor 14 Monarch Ozone System Optional 16 PureWater Ozone System Optional 16 Common...

Страница 4: ...protection To ensure proper operation of this important safety device test according to the following instructions per electrical configuration Cord Connected 115 volt 15 and 20 amp models The GFCI is...

Страница 5: ...pa if the suction fittings are broken or missing People with infectious diseases should not use the spa Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving c...

Страница 6: ...n additional SAFETY SIGNS contact your Caldera dealer and request Part 003021 IMPORTANT SPA INSTRUCTIONS The following contains important spa information and we strongly encourage you to read and appl...

Страница 7: ...l requirements if you place your spa indoors Water will accumulate around the spa so flooring materials must provide a good grip when wet Proper drainage is essential to prevent a build up of water ar...

Страница 8: ...odule showing where the connections are to be made ELECTRICAL REQUIREMENTS AND PRECAUTIONS Your Caldera spa has been carefully designed to give you maximum safety against electrical shock Connecting t...

Страница 9: ...service to the subpanel terminal L1 3 Connect the 8 AWG RED L2 wire from the main electrical service to the subpanel terminal L2 4 Connect the 10 AWG GREEN wire from the Neutral Ground Bar on the main...

Страница 10: ...r compartment with the jet pump on high speed for at least ten minutes OPERATION NOTE Adjusting the Total Alkalinity as the first step is important as out of balance TA will affect your ability to adj...

Страница 11: ...compartment 4 Temperature sensor 5 Spa light OLYMPIA MODEL SHOWN FEATURES AND LOCATIONS WILL VARY IN OTHER MODELS 3 1 2 4 5 6 9 6 Drain suction fitting 7 Outlet for optional ozone 8 Magna Jets 9 Euro...

Страница 12: ...et button changes the jet pump functions depending on the number of presses Oympia Spa only 1st press Two speed jet pump runs on low speed 2nd press Two speed jet pump runs on high speed 3rd press One...

Страница 13: ...ed the FILTER LED will blink Once the jet pump has been shut off a ten minute tranquil mode begins FILTER LED will be blinking during tranquil mode before the filter cycle will resume The blinking fil...

Страница 14: ...ly and follow directions precisely Though chemicals protect you and your spa when used correctly they can be hazardous in concentrated form Always observe the following guidelines Allow only a respons...

Страница 15: ...evel for your spa is 150 200 ppm B Calcium Hardness is a measure of the total amount of dissolved calcium in the water Calcium helps control the corrosive nature of the spa s water That s why calcium...

Страница 16: ...water It is important to follow the recommended application and maintenance programs outlined for each product s use If the spa is being used over an extended period or time such as a whole afternoon...

Страница 17: ...ontaminants in the water may coat the silver cartridge s ceramic beads blocking the silver ions release into the water When this occurs there will be no residual of silver ions present in the water el...

Страница 18: ...e amount of time a user spends in the spa Sanitizer Needed is the amount of Free Available Chlorine FAC needed to accommodate the number of users and their combined usage time For example two spa user...

Страница 19: ...Watkins Manufacturing Corporation recommends that a chemical maintenance program based on recognized and documented industry standards still be followed when using an ozone purification system to ass...

Страница 20: ...or or seat of the spa shell These pieces of sanitizer will chemically burn blister the spa shell Although your spa shell is specifically designed to resist the effects of spa chemicals no spa surface...

Страница 21: ...is caused by mineral content combined with high pH Additionally scale forms more readily at higher water temperatures Shock Treatment Also known as super chlorination when chlorine is used Shock treat...

Страница 22: ...the clear lens to create the desired ambiance SPA LIGHT BULB REPLACEMENT To replace the spa light bulb disconnect power to the spa 1 Remove equipment compartment door 2 Locate the rear of the spa lig...

Страница 23: ...lons of water or baking soda sodium bicarbonate scrub the vinyl top in a circular motion Do not let the vinyl dry with a soap film on it before it can be rinsed clean 4 Scrub the cover s perimeter and...

Страница 24: ...not covered by warranty WINTERIZING YOUR SPA If the spa is located where freezing temperatures occur and you do not intend to use your spa for an extended period follow steps 1 through 7 outlined in D...

Страница 25: ...surface material can withstand this kind of abuse damage to components or spa surface caused by improper water chemistry maintenance and damage to the spa surface caused by leaving the spa uncovered w...

Страница 26: ...clogged filter If tripping continues call for service Check for clogged filter The pressure switch will reset when the flow of water through the heater has been restored Call for service if the pressu...

Страница 27: ......

Страница 28: ...amp Dedicated GFCI protected cord or 230 volt 50 amp Single phase GFCI circuit 7 0 x 7 0 Olympia 36 75 square feet 4 000 360 gallons 706 lbs 4 744 lbs 100 lbs per square foot 230 volt 30 50 amp Singl...