background image

TO REDUCE THE RISK OF INJURY:

• The water in the spa should never exceed 104°F. Water temperatures between 100°F and 104°F are considered safe for a healthy adult. Lower water

temperatures are recommended for extended use (exceeding 10 minutes) and for young children. Extended use can cause hyperthermia.

• Pregnant or possibly pregnant women should limit spa water temperatures to 100°F. Failure to do so may result in permanent injury to your baby.
• Do not use spa immediately following strenuous exercise.

AVOIDING THE RISK OF SKIN BURNS:

• To reduce the risk of injury, before entering a spa the user should measure the water temperature with an accurate thermometer, since the tolerance of

temperature-regulating devices may vary by as much as ±5°F.

• Test the water with your hand before entering the spa to be sure it’s comfortable.

SAFETY SIGN

Each Caldera

®

spa is shipped with a SAFETY SIGN in the owner’s package. The sign, which is required as a condition of Product Listing, should be permanently

installed where it is visible to the users of the spa. To obtain additional SAFETY SIGNS, contact your Caldera dealer and request Part #003021.

IMPORTANT SPA INSTRUCTIONS

The following contains important spa information, and we strongly encourage you to read and apply them.

DO:

• Use and lock the vinyl cover when the spa is not in use, whether it is empty or full.
• Follow the Spa Care and Maintenance recommendations stated in this manual.
• Use only approved accessories and recommended spa chemicals and cleaners.

DON’T:

• Leave the spa exposed to the sun without water or the vinyl cover in place. Exposure to direct sunlight can cause solar distress of the shell material.
• Roll or slide the spa on its side. This will damage the siding.
• Lift or drag the cover by using the cover lock straps; always lift or carry the cover by using the handles.
• Attempt to open the electrical control box. There are no user serviceable parts inside. Opening of the control box by the spa owner will void the warranty. If you

have an operational problem, carefully go through the steps outlined in the Troubleshooting section. If you are not able to resolve the problem, contact your
authorized Caldera dealer. Many problems can easily be diagnosed over the telephone by an Authorized Service Technician.

SAVE THESE INSTRUCTIONS

SAFETY INFORMATION

3

Содержание Olympia

Страница 1: ...OWNER S MANUAL H i g h l a n d S e r i e s Olympia Cascade CumberlandTM...

Страница 2: ...____________________________ SPA MODEL SERIAL NUMBER ______________________________ COVER SERIAL NUMBER ____________________________________ In most cities and counties permits will be required for th...

Страница 3: ...l Information 11 Methods for Testing the Spa Water 11 The Watkins Spa Water Maintenance Program 12 Chlorine sodium dichlor 14 Monarch Ozone System Optional 16 PureWater Ozone System Optional 16 Common...

Страница 4: ...protection To ensure proper operation of this important safety device test according to the following instructions per electrical configuration Cord Connected 115 volt 15 and 20 amp models The GFCI is...

Страница 5: ...pa if the suction fittings are broken or missing People with infectious diseases should not use the spa Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving c...

Страница 6: ...n additional SAFETY SIGNS contact your Caldera dealer and request Part 003021 IMPORTANT SPA INSTRUCTIONS The following contains important spa information and we strongly encourage you to read and appl...

Страница 7: ...l requirements if you place your spa indoors Water will accumulate around the spa so flooring materials must provide a good grip when wet Proper drainage is essential to prevent a build up of water ar...

Страница 8: ...odule showing where the connections are to be made ELECTRICAL REQUIREMENTS AND PRECAUTIONS Your Caldera spa has been carefully designed to give you maximum safety against electrical shock Connecting t...

Страница 9: ...service to the subpanel terminal L1 3 Connect the 8 AWG RED L2 wire from the main electrical service to the subpanel terminal L2 4 Connect the 10 AWG GREEN wire from the Neutral Ground Bar on the main...

Страница 10: ...r compartment with the jet pump on high speed for at least ten minutes OPERATION NOTE Adjusting the Total Alkalinity as the first step is important as out of balance TA will affect your ability to adj...

Страница 11: ...compartment 4 Temperature sensor 5 Spa light OLYMPIA MODEL SHOWN FEATURES AND LOCATIONS WILL VARY IN OTHER MODELS 3 1 2 4 5 6 9 6 Drain suction fitting 7 Outlet for optional ozone 8 Magna Jets 9 Euro...

Страница 12: ...et button changes the jet pump functions depending on the number of presses Oympia Spa only 1st press Two speed jet pump runs on low speed 2nd press Two speed jet pump runs on high speed 3rd press One...

Страница 13: ...ed the FILTER LED will blink Once the jet pump has been shut off a ten minute tranquil mode begins FILTER LED will be blinking during tranquil mode before the filter cycle will resume The blinking fil...

Страница 14: ...ly and follow directions precisely Though chemicals protect you and your spa when used correctly they can be hazardous in concentrated form Always observe the following guidelines Allow only a respons...

Страница 15: ...evel for your spa is 150 200 ppm B Calcium Hardness is a measure of the total amount of dissolved calcium in the water Calcium helps control the corrosive nature of the spa s water That s why calcium...

Страница 16: ...water It is important to follow the recommended application and maintenance programs outlined for each product s use If the spa is being used over an extended period or time such as a whole afternoon...

Страница 17: ...ontaminants in the water may coat the silver cartridge s ceramic beads blocking the silver ions release into the water When this occurs there will be no residual of silver ions present in the water el...

Страница 18: ...e amount of time a user spends in the spa Sanitizer Needed is the amount of Free Available Chlorine FAC needed to accommodate the number of users and their combined usage time For example two spa user...

Страница 19: ...Watkins Manufacturing Corporation recommends that a chemical maintenance program based on recognized and documented industry standards still be followed when using an ozone purification system to ass...

Страница 20: ...or or seat of the spa shell These pieces of sanitizer will chemically burn blister the spa shell Although your spa shell is specifically designed to resist the effects of spa chemicals no spa surface...

Страница 21: ...is caused by mineral content combined with high pH Additionally scale forms more readily at higher water temperatures Shock Treatment Also known as super chlorination when chlorine is used Shock treat...

Страница 22: ...the clear lens to create the desired ambiance SPA LIGHT BULB REPLACEMENT To replace the spa light bulb disconnect power to the spa 1 Remove equipment compartment door 2 Locate the rear of the spa lig...

Страница 23: ...lons of water or baking soda sodium bicarbonate scrub the vinyl top in a circular motion Do not let the vinyl dry with a soap film on it before it can be rinsed clean 4 Scrub the cover s perimeter and...

Страница 24: ...not covered by warranty WINTERIZING YOUR SPA If the spa is located where freezing temperatures occur and you do not intend to use your spa for an extended period follow steps 1 through 7 outlined in D...

Страница 25: ...surface material can withstand this kind of abuse damage to components or spa surface caused by improper water chemistry maintenance and damage to the spa surface caused by leaving the spa uncovered w...

Страница 26: ...clogged filter If tripping continues call for service Check for clogged filter The pressure switch will reset when the flow of water through the heater has been restored Call for service if the pressu...

Страница 27: ......

Страница 28: ...amp Dedicated GFCI protected cord or 230 volt 50 amp Single phase GFCI circuit 7 0 x 7 0 Olympia 36 75 square feet 4 000 360 gallons 706 lbs 4 744 lbs 100 lbs per square foot 230 volt 30 50 amp Singl...

Отзывы: