background image

Owner’s Manual

This Owner’s Manual will acquaint you with the operation and general maintenance of your new spa. We suggest that you
take some time to carefully review all sections. Please keep this manual available for reference.

If you have any questions about any aspect of your spa’s set-up, operation or maintenance, contact your authorized Caldera
dealership. They are trained professionals who are familiar with the product as well as new spa ownership concerns. Their
expertise will facilitate the enjoyment of your new Caldera spa.

The serial number/identification label is located within the equipment compartment of your Caldera spa. The serial number
should also be documented on the delivery receipt from your dealer.

IMPORTANT:

Watkins Manufacturing Corporation reserves the right to change specifications, or design, without notification

and without incurring any obligation.

DATE PURCHASED:  ________________________________________

DATE INSTALLED:____________________________________________

DEALER: ____________________________________________________

ADDRESS: __________________________________________________

TELEPHONE: ________________________________________________

SPA MODEL/SERIAL NUMBER: ______________________________

COVER SERIAL NUMBER: ____________________________________

In most cities and counties, permits will be required for the installation of electrical circuits or the construction of exterior surfaces (decks and gazebos).

In addition, some communities have adopted residential barrier codes which may require fencing and/or self-closing gates on the property to prevent

unsupervised access to a pool (or spa) by children under 5 years of age. Your Caldera spa is equipped with a locking cover that meets the ASTM

F1346-91 Standard for Safety Covers, and as a result, is usually exempt from most barrier requirements. As a general practice, your local Building

Department will inform you of any applicable barrier requirements at the time a permit is obtained for the installation of an electrical circuit. Your Caldera

dealer can provide information on which permits may be required.

Watkins

®

Manufacturing Corporation congratulates you on your decision to enjoy the finest spa available...

Welcome to the growing family of Caldera

®

Spa owners.

NOTE:

This is an example. Your spa’s

label will contain different information.
Peel off top sticker and place here.

MODEL:

OLYMPIA

SERIES:

HIGHLAND

SERIAL:

OLH1E1001

RATINGS:

240V, 60HZ, 30A

OLH1E1001

OLH1E1001

OLH1E1001

OLH1E1001

OLH1E1001

WELCOME

Содержание Olympia

Страница 1: ...OWNER S MANUAL H i g h l a n d S e r i e s Olympia Cascade CumberlandTM...

Страница 2: ...____________________________ SPA MODEL SERIAL NUMBER ______________________________ COVER SERIAL NUMBER ____________________________________ In most cities and counties permits will be required for th...

Страница 3: ...l Information 11 Methods for Testing the Spa Water 11 The Watkins Spa Water Maintenance Program 12 Chlorine sodium dichlor 14 Monarch Ozone System Optional 16 PureWater Ozone System Optional 16 Common...

Страница 4: ...protection To ensure proper operation of this important safety device test according to the following instructions per electrical configuration Cord Connected 115 volt 15 and 20 amp models The GFCI is...

Страница 5: ...pa if the suction fittings are broken or missing People with infectious diseases should not use the spa Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving c...

Страница 6: ...n additional SAFETY SIGNS contact your Caldera dealer and request Part 003021 IMPORTANT SPA INSTRUCTIONS The following contains important spa information and we strongly encourage you to read and appl...

Страница 7: ...l requirements if you place your spa indoors Water will accumulate around the spa so flooring materials must provide a good grip when wet Proper drainage is essential to prevent a build up of water ar...

Страница 8: ...odule showing where the connections are to be made ELECTRICAL REQUIREMENTS AND PRECAUTIONS Your Caldera spa has been carefully designed to give you maximum safety against electrical shock Connecting t...

Страница 9: ...service to the subpanel terminal L1 3 Connect the 8 AWG RED L2 wire from the main electrical service to the subpanel terminal L2 4 Connect the 10 AWG GREEN wire from the Neutral Ground Bar on the main...

Страница 10: ...r compartment with the jet pump on high speed for at least ten minutes OPERATION NOTE Adjusting the Total Alkalinity as the first step is important as out of balance TA will affect your ability to adj...

Страница 11: ...compartment 4 Temperature sensor 5 Spa light OLYMPIA MODEL SHOWN FEATURES AND LOCATIONS WILL VARY IN OTHER MODELS 3 1 2 4 5 6 9 6 Drain suction fitting 7 Outlet for optional ozone 8 Magna Jets 9 Euro...

Страница 12: ...et button changes the jet pump functions depending on the number of presses Oympia Spa only 1st press Two speed jet pump runs on low speed 2nd press Two speed jet pump runs on high speed 3rd press One...

Страница 13: ...ed the FILTER LED will blink Once the jet pump has been shut off a ten minute tranquil mode begins FILTER LED will be blinking during tranquil mode before the filter cycle will resume The blinking fil...

Страница 14: ...ly and follow directions precisely Though chemicals protect you and your spa when used correctly they can be hazardous in concentrated form Always observe the following guidelines Allow only a respons...

Страница 15: ...evel for your spa is 150 200 ppm B Calcium Hardness is a measure of the total amount of dissolved calcium in the water Calcium helps control the corrosive nature of the spa s water That s why calcium...

Страница 16: ...water It is important to follow the recommended application and maintenance programs outlined for each product s use If the spa is being used over an extended period or time such as a whole afternoon...

Страница 17: ...ontaminants in the water may coat the silver cartridge s ceramic beads blocking the silver ions release into the water When this occurs there will be no residual of silver ions present in the water el...

Страница 18: ...e amount of time a user spends in the spa Sanitizer Needed is the amount of Free Available Chlorine FAC needed to accommodate the number of users and their combined usage time For example two spa user...

Страница 19: ...Watkins Manufacturing Corporation recommends that a chemical maintenance program based on recognized and documented industry standards still be followed when using an ozone purification system to ass...

Страница 20: ...or or seat of the spa shell These pieces of sanitizer will chemically burn blister the spa shell Although your spa shell is specifically designed to resist the effects of spa chemicals no spa surface...

Страница 21: ...is caused by mineral content combined with high pH Additionally scale forms more readily at higher water temperatures Shock Treatment Also known as super chlorination when chlorine is used Shock treat...

Страница 22: ...the clear lens to create the desired ambiance SPA LIGHT BULB REPLACEMENT To replace the spa light bulb disconnect power to the spa 1 Remove equipment compartment door 2 Locate the rear of the spa lig...

Страница 23: ...lons of water or baking soda sodium bicarbonate scrub the vinyl top in a circular motion Do not let the vinyl dry with a soap film on it before it can be rinsed clean 4 Scrub the cover s perimeter and...

Страница 24: ...not covered by warranty WINTERIZING YOUR SPA If the spa is located where freezing temperatures occur and you do not intend to use your spa for an extended period follow steps 1 through 7 outlined in D...

Страница 25: ...surface material can withstand this kind of abuse damage to components or spa surface caused by improper water chemistry maintenance and damage to the spa surface caused by leaving the spa uncovered w...

Страница 26: ...clogged filter If tripping continues call for service Check for clogged filter The pressure switch will reset when the flow of water through the heater has been restored Call for service if the pressu...

Страница 27: ......

Страница 28: ...amp Dedicated GFCI protected cord or 230 volt 50 amp Single phase GFCI circuit 7 0 x 7 0 Olympia 36 75 square feet 4 000 360 gallons 706 lbs 4 744 lbs 100 lbs per square foot 230 volt 30 50 amp Singl...

Отзывы: