background image

N I A G A R A

Niagara UV Spa

Owners Manual 
228 x 228 x 99cm (90 x 90 x 39")
KH-10024

For Service Support please contact us anytime:  

support.canadianspacompany.com

canadianspacompany.com

Содержание Niagara UV Spa KH-10024

Страница 1: ...N I A G A R A Niagara UV Spa Owners Manual 228 x 228 x 99cm 90 x 90 x 39 KH 10024 For Service Support please contact us anytime support canadianspacompany com canadianspacompany com ...

Страница 2: ...sult in voiding the manufacturer s warranty 16 Do not bring any object into the spa that could damage the spa shell 17 Never insert any object into any opening 18 WARNING Do not sit on the spa cover or place objects on it 19 Remove any water or debris that may collect on the spa cover 20 WARNING Do not use the spa immediately after strenuous exercise 21 If you feel pain or dizziness at any time wh...

Страница 3: ...DRAIN VALVE Valve located on the outside of spa cabinet used to drain water from the spa A garden hose can be attached to the drain valve EQUIPMENT BAY Located under the spa shell covered by access panels that houses the spa controller and equipment SLICE VALVE Two position open or closed sliding valve used to cut off water flow which allows for service to be performed on the spa equipment without...

Страница 4: ... are aware of the above measurements Always consider during your planning that any decking boards and supporting beams that you install allow access to the sides of your Spa It is the customers responsibility to ensure that any decking is clear of these areas prior to any visit by our technicians Allow 1 metre clearance around your hot tub and if you have decking ensure part of your decking can be...

Страница 5: ...sition Draining your Spa Using drain valve IMPORTANT Before draining your spa shut off the electrical breaker connected to the spa Accessing your spa controls To access the Control Pack undo the 3 screws on both panel strips Installation Electrical power requirements Power connections Single Phase A is the normal wiring configuration for most household electrical installations 3 wires live neutral...

Страница 6: ...DIP switches A2 and A3 on ON and DIP switch A5 on OFF B 2 x Single Phase live 1 neutral 1 live 2 neutral 2 ground 230VAC 50 60Hz 2þ 16A Circuit Breaker rating 20A max each phase line In 2x16A Service Pump 2 if any and the Heater are on one service Everything else is on the other service For 2 Wire connection 1 Completely remove jumper on J51 and J88 2 Completely remove jumper on J52 and J62 3 Make...

Страница 7: ...a Flush Annually flush the spa to remove bio film that has attached to the interior of the spa pipes KA 10164 Spa Functions Pumps Press the Jets 1 button once to turn pump 1 on or off and to shift between low and high speeds if equipped If left running the pump will turn off after a time out period The pump 1 low speed will time out after 30 minutes The high speed will time out after 15 minutes Th...

Страница 8: ...pa Company channel pH LOW pH HIGH pH NORMAL 7 2 7 6 Reduced efficacy of disinfection Corrosion of metals Skin eye irritation Unpleasant odour Reduced efficacy of disinfection Skin eye irritation Forms limescale deposits Staining of the filter pH SCALE Low PH and low quality chlorine causes the heater element to calcify Canadian Spa Company Spa Ball KA 10003 Helps to keep your spa clean and achieve cr...

Страница 9: ...cle duration Based on usage adjust filtration cycle duration High solids content See common water problem section Settings 2 x Pumps standard Simple Options Press Menu button until you reach the mode you require TEMP Temp Up button until arrow is either pointing up or down Arrow up will maintain heat Arrow down will drop the temp by 10 degrees Menu button to select MODE Temp Up button press until ...

Страница 10: ...mp off and on will help it to prime Do not do this more than 5 times If the pump will not prime shut off the power to the spa and call for service Important A pump should not be allowed to run without priming for more than 2 minutes Under NO circumstances should a pump be allowed to run without priming beyond the end of the 4 5 minute priming mode Doing so may cause damage to the pump and cause th...

Страница 11: ...arted at noon the filter cycles will run as programmed Flip Invert Display Restricting Operation The control can be restricted to prevent unwanted use or temperature adjustments Locking the panel prevents the controller from being used but all automatic functions are still active Locking the Temperature allows Jets and other features to be used but the Set Temperature and other programmed settings...

Страница 12: ...ill last for 1 hour unless the mode is exited manually Drain Mode Some spas have a special feature that allows a pump to be employed when draining the water When available this feature is a component of Hold Mode Drain Mode will time out with Hold Mode Sub Menu Detail User Preferences 05 15 09 Preferences F C Temp Display Change the temperature between Fahrenheit and Celsius 12 24 Time Display Not...

Страница 13: ... start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below Heater is Dry MO27 There is not enough water in the heater to start it The spa is shut down After the problem has been resolved you must press any button to reset and restart heater start up See Flow Related Checks RUN PMP5 PURG AIR C TOO COLD WATR TOO HOT CHNG WATR CLN COVR CLN CH...

Страница 14: ...days can be specified by the Manufacturer Press a Temperature button to reset a displayed reminder message Alternates with temperature or normal display Appears on a regular schedule e g every 7 days Check pH with a test kit and adjust pH with the appropriate chemicals Alternates with temperature or normal display Appears on a regular schedule e g every 7 days Check sanitizer level and other water...

Страница 15: ...ing of chemicals Normal fading and minor deterioration or failure to leave the cover open 30 minutes after adding chemicals Inner foam core breakage Misuse neglect negligence accident or alterations other than authorised by Canadian Spa Company TERMS CONDITIONS AND LIMITATIONS Any defect or damage caused by installation alteration or repair by anyone who is not an employee of Canadian Spa Co or au...

Отзывы: