INNOVATION TOTAL LITE Rev. 11 05/2018
65
www.cafection.com 800-561-6162
SERVICE & INSTALLATION MANUAL for Innovation Series’ Total Lite
C
le
an
in
g
an
d
San
it
iz
in
g
Brew Group Assembly Sanitizing Treatment
Frequency: quarterly or every 5,000 cycles
Regular sanitation treatments of the brew group assembly prevent residue from affecting
the vacuum in the mechanism and altering the taste of the beverages.
1. Open the machine door and place a recipient large
enough under the dispensing nozzle.
2. Brush away any loose coffee on the brew group
and remove filter paper.
3. Clean the stainless coffee chute and plug it with a
towel.
4. Sprinkle one (1) portion of urn cleaner directly into
the brew chamber.
5. In Service mode, access the Liquids & Ingr. subtab
(under the Recipes tab). Press on the "Get a Large
Sample" button, then press on the "Water Only"
button.
6. When water mixes with the urn cleaner, stir
around with a paintbrush. As soon as water stops
dispensing, turn off the machine.
7. Allow the cylinder to soak for five (5) minutes, then
turn the machine back on. Wait for the machine to reboot completely in order for the
brew group to finish the water cycle.
8. Perform several auto rinse cycles (see section 7.1) until water comes out clean.
9. Reinstall the filter paper and remove the towel from the stainless coffee chute.
10. Order two (2) coffee drinks to complete the filter paper installation, then close the door.
7.7.4 Fan
Frequency: quarterly or as needed
Visually inspect the fan located
directly to the right of the hot
chocolate canister and clean if
needed.
1. Turn off the unit and unplug it
to stop the fan.
2. Unplug the fan and remove
the guard to access the fan
blades.
3. Wipe the fan clean with a dry
disposable towel.
4. Reinstall the guard, plug the
machine in and turn it back
ON.
Fan