INNOVATION TOTAL LITE Rev. 11 05/2018
www.cafection.com 800-561-6162
44
SERVICE & INSTALLATION MANUAL for Innovation Series’ Total Lite
6.5.3 Brew Cycles & Fast Settings Subtab
Brew Cycle Settings Interface
1. This table is used to set the brew cycles and extra grind time. Press on the quantity to
modify and enter the desired number of units using the numeric keyboard.
2. This button is used to bring all brew cycles values to factory settings.
3. This button is used to exit the brew cycles settings.
To save any parameters change, press on the "Exit" button
and accept modifications.
The Total Lite has four (4) different brew cycles. The brew cycle is automatically selected in
accordance with the coffee and water quantities in the coffee-based recipe.
Cycle #1 (101 to 187 water units)
Standard brew cycle.
Cycle #2 (188 to 269 water units)
Three (3) stirring cycles when the total quantity of water is dispensed in three (3) shots. The
mix is stirred three (3) times, ensuring that the coffee completely comes into contact with
water. Ideal for recipes with high water and coffee volumes.
Cycle #3 (270 water units and more)
Double brew cycle. The machine splits the water and ingredients quantities in half to
perform two (2) separated brew cycles.
Cycle #4 (100 water units or less)
Quick brew cycle. Ideal for recipes with low water level.
Extra Grind Time
The grind time is automatically calculated in accordance with the quantity of coffee beans
set in the recipe. Old grinders might not grind all the beans. Therefore, extra grind time may
be added using these fields.
20 units = 1 second. Default setting: 0.
Pause 1
First contact time between water and coffee grounds. To get more extraction, increase this
value.
20 units = 1 second.
Pause 2
Second contact time between water and coffee grounds. To get more extraction, increase
this value.
20 units = 1 second.
1
3
2
S
e
rv
ic
e Mo
d
e