8.4
Water Tank
Inspection: quarterly
Preventive maintenance: every 60,000 cycles
To avoid any issue related to mineral
deposits, Cafection recommends having
the water tank assembly delimed to remove
all scale in the unit. The heating element,
the temperature probe, the water level and
heater safety switches may also need to be
replaced.
Use a scale remover product such
as
Scale Kleen
by Everpure. See the
manufacturer’s instructions for more
details.
The float, the heater
switch and the water
level switch of the tank
should be replaced
after 100,000 cycles.
Heater safety
switch
Water level switch
Heating
element
Float
Probe