![background image](http://html1.mh-extra.com/html/caen/dt5495/dt5495_user-manual_3276608041.webp)
CAEN
Electronic Instrumentation
UM6508
–
DT5495 User Manual rev. 0
41
➢
Local Bus ports:
The Local Bus signals are shown in
Tab. 10.8
.
SIGNAL NAME
WIDTH
TYPE
DESCRIPTION
nLBRES
1
Input
Bus reset (active low)
nBLAST
1
Input
Last cycle (active low)
WnR
1
Input
Write/Read cycle
0 = read
1 = write
nADS
1
Input
Address strobe (active low)
nREADY
1
Output
Slave ready/Prefetch request
LAD
32
Input/Ou
tput
Data/address bus
Tab. 10.8:
Local Bus ports description table