13
5
Installation
5.1
Factory default Settings
i
Note!
The applicator is set up in a standard configuration by the factory. These values guarantee a smooth
operation.
i
Note!
In the case of a customer specific setup with special material the settings can deviate from the standard
values.
In this case the standard values in the setup protocol are as follows.
The factory default settings are:
•
Connected to a cab printer, vertical
•
Used Pad:
cab part No.: 5963881 54x36 for L
cab part No.: 5963878 54x36 for R
•
Material used for factory default settings:
cab part No.: 5556472 54x35.5
•
Pressure value of the compressed air:
0.45 MPa (4.5 bar)
•
Factory setting sensors
Cylinder Z
„6.8 Lift Speed of Cylinder Z“
Cylinder X/Y
„6.13 Sensors on Cylinder X/Y“
•
Factory settings throttle valves
Cylinder Z
„6.8 Lift Speed of Cylinder Z“
Cylinder X/Y
„6.12 Lift Speed of Cylinder X/Y“
5.2
Tools
Screwdriver with parallel blade
2.5
•
To adjust the throttle valves
and product sensor
Hexagon key L-wrench
0.8
•
To adjust the sensors
(in contents of delivery)
2.5
•
For matched norm parts
(in contents of delivery)
4
•
Pad adjustments
Changing pad
Flat-round nose
straight
angled
•
To mount/dismount tubes
Open spanner
SW 8
•
To change the throttle valves
SW 13
•
Setting the spring strength of
the adapter bolt
SW20
•
Changing the cylinder
Manometer
± 7 bar
•
Air pressure control
Содержание 4414 Series
Страница 1: ...Service Manual 4414 MADE IN GERMANY Stroke Applicator...
Страница 36: ...36 36 9 Drawings 9 2 Pneumatic drawing Type 4414 Fig 40 Pneumatics Type 4414...
Страница 37: ...37 9 Drawings 9 3 Label position Type 4414 L Fig 41 Label position 4414L...