iNetVu™ Service Manual
Page 62 of 109
c. Ensure that there are no red indicators flashing.
d. Verify that the Azimuth Angle is approximately 0 + 10
.
Fig. 18:
Manual Controls
I. If the Azimuth Angle is not approximately 0 + 10
, switch to
CONFIG
mode.
II. Go to
Maintenance
.
III. Verify that the
Pot Zero
and
Pot Factor
in the Azimuth Parameters
match the following table. These are the default values that your
system should be operating with.
Fig. 19:
Azimuth Potentiometer Parameters
IV. Restore to default values if required and click
Send AZ/Send All.
Click
Yes
when asked to save to the EPROM.
Fig. 20:
Azimuth Parameters in the Maintenance Menu
V. Verify Azimuth Angle again.
e. Set
Elevation
to 25.0
f. Set
both
Azimuth
and
Polarization
to 0.0.
g. Click
Deploy Dish
to raise the dish.
h. Set
Duration
to 50 x 50ms
i. Set
Speed
to 9