iNetVu™ Service Manual
Page 28 of 109
3.2.1.4. Elevation Current Limit Error
Cause 1:
Current used to move the Elevation exceeds the fixed limit, which resulted
in a current spike. The Mobile Platform may have been obstructed by a
foreign object and does not have enough clearance to elevate up or down.
Solution 1:
Ensure that the path of the Elevation arm has enough clearance for free
movement.
Cause
2:
Elevation Current limit is set too low.
Solution 2 (5000/9000 Controllers):
1. Switch to
CONFIG
mode
2. Go to
Maintenance
.
3. Click
Advanced
.
Verify the default speeds and currents are set (see Appendix A –
5000/9000 Controller)
Solution 2 (7000 Controller)
1.
Go to
Maintenance
2.
Ensure Elevation Slow Speed is the default value (verify with 7000
Manual)
3. Ensure the Current @ Speed 9 and the Current @ Speed 6 are default
values (verify with Appendix B - 7000 Controller)