4.1. ST/UP/DN Limit Adjustments
Products Affected:
ME-Generation Mobile Platforms
A-Generation Mobile Platforms
Description:
This article describes the steps involved for adjusting the Elevation Limit Switches
on all ME & A Generation Mobile Platforms.
Required Materials:
½” Wrench
Phillips Screwdriver
Operational Requirement:
Space between Limit Switch and Magnet Bracket must be
3mm to 5 mm
.
Once space requirement is met, re-position Magnet Bracket in order to adjust
the angle at which the Limit Switch is triggered.