Solution(s):
Use the following steps to adjust the Limit Switches:
Up (UP) Limit Switch
The Elevation Up Limit Switch Indicator should be ON above:
65
for 0.74/0.95/0.98 Mobile Platforms
75
for 1.2/1.8 Mobile Platforms
1)
Remove Elevation Cover.
2)
Locate Elevation Up Limit Switch.
3)
Start iNetVu Mobile Software.
4)
Go to
Advanced Controls
.
5)
Set
Elevation
to 60 (70 for 1.2 Mobile Platforms),
Azimuth
to 0, and
Polarization
to 0 in Manual Controls.
6)
Click
Deploy Dish
.
7)
Adjust the space between the Limit Switch and Magnet to
3-5 mm
by loosening
the Locking Nuts and sliding the Limit Switch either closer to or further from the
Limit Switch, and also adjusting the position of the Magnet Block to help
accommodate the
3-5 mm
gap.
Typically, there are approximately 6-7 threads of the Limit Switch exposed
on the base.
8)
Set
Duration
to 10 and
Speed
to 7.
9)
Click
Elevation Up
, until the Elevation UP Indicator comes ON, and you receive
an “Elevation UP Limit Error”.
10)
If the Elevation Angle is less than 65
(75
for 1.2 Mobile Platforms), lower the
Elevation and re-adjust the magnet block, by loosening the locking screws until
satisfactory results are met.
It is imperative to maintain the 3-5 mm gap between the Limit Switch and Magnet
at the Elevation at which the Elevation UP Indicator comes ON.
Содержание iNetVu
Страница 5: ...iNetVu Service Manual Page 5 of 109...
Страница 40: ...iNetVu Service Manual Page 40 of 109 4 REPAIRS AND REPLACEMENTS...
Страница 91: ...iNetVu Service Manual Page 91 of 109 6 Congratulations The transmit polarization has been successfully adjusted...
Страница 104: ...iNetVu Service Manual Page 104 of 109 4 Congratulations The flexible waveguide has been successfully attached...