iNetVu™ Service Manual
Page 51 of 109
Direct Connection to 12VDC Power Supply
In the event that the iNetVu™ 5000/7000/9000 Controller experiences system failure, a
direct connection from the Motor Control cable wires to a 12VDC power supply is
required.
The following is a summary of the wire pairs, the parameter that they control and the
appropriate polarity for moving the motors.
5000 Controller
Elevation: Red-Black
Azimuth: White-Blue
Polarization: Green-Orange/Brown
Elevation UP
(-) RED
(+) BLACK
Elevation DOWN
(+) RED
(-) BLACK
Azimuth CW
(-) WHITE
(+) BLUE
Azimuth CCW
(+) WHITE
(-) BLUE
Polarization CW
(-) GREEN
(+)
ORANGE/BROWN
Polarization CCW
(+) GREEN
(-) ORANGE BROWN
1) Disconnect Motor Control cable from the iNetVu™ 5000 Controller.