iNetVu™ Service Manual
Page 30 of 109
3.2.2. Azimuth Related
3.2.2.1. Azimuth Current Limit Error
Cause 1:
Current used to move the Azimuth exceeds the fixed limit, which resulted
in a current spike. The Mobile Platform may have been obstructed by a
foreign object and does not have enough clearance to rotate left or right.
Solution 1:
Ensure that the Azimuth path has enough clearance for free movement.
Cause 2:
Azimuth Current limit is set too low.
Solution 2:
Verify the default slow speed on the Azimuth, and Default Current Limits
depending on the controller and platform type. Modify if Required.
5000 / 9000 – Go to Advanced in the Maintenance Menu (ensure your in
configuration mode)
7000 Controller – Go to the Maintenance Menu, and check in the Azimuth
section.
See appendix for details on default speeds and limits.