2019/08 - Indice de révision : D - Code : 29650
TRAITEMENT DE L'EAU
58/72
!
IMPORTANT
The correlation between the Redox potential and the desired free Chlorine concentration
should be re-established:
•
Each year when the pool is reopened, if the pool was winterized
•
if a significant volume of the pool water (more than 1/3) is renewed
•
if a decision to alter the stabiliser concentration is made
To do this you will need a photometer capable of measuring the Chlorine concentration with adequate
precision, and that has been calibrated within the last year; if necessary adjust the concentration by
adding small amounts of Chlorine successively, until the required concentration is reached. Note the
Redox potential measured by EES Pro, this is the set point. If a regular drift from the Redox value is
noticed, or if there is a sudden change in this value, replace the Redox sensor.
!
ATTENTION
The Redox system does not allow precise regulation of the free Chlorine concentration
at high set point values (above 2 ppm, that is approximately 725 mV at pH = 7.4).
8.4
Turbo mode
The Turbo function allows continual production of Chlorine at maximum output (100%) over a duration
set by the user.
Press the button to switch to Turbo mode: the word Turbo blinks at the bottom of the output scale.
The Turbo mode duration is set to 12 hours in the factory, this setting is displayed on screen.
Successive presses on the T button will increase the duration in increments of 12 hours up to a maximum
duration of 72 hours (then returns to 0).
For finer adjustment, in intervals of one minute, use the arrow keys, ▲ and ▼.
EXAMPLE:
To activate Turbo mode for a duration of 26 hours and 30 minutes. After having activated Turbo mode,
press the T button once -> 24:00 is displayed. To set the minutes, keep the ▲ key pressed down (rapid
scroll) and then press successively until 26:30 is displayed. If the value is overshot, use the ▼ key to
return to the desired value.
Next, the displayed time will start to count down, this represents the time remaining for the Turbo cycle.
!
IMPORTANT
begin setting the duration of the Turbo cycle with the T button within 5 seconds of
entering Turbo mode. Each successive press on the T button to modify the length of the cycle must
occur within 5 seconds of the last. Otherwise, pressing the T button will cause the device to exit Turbo
mode.
There are 3 ways to exit Turbo mode:
•
allow more than 5 seconds to elapse and then press the T button.
•
stop the device using the ON/OFF button
•
set the duration of the cycle to 00 : 00
Neither activation nor exiting Turbo mode will effect settings in AUTO mode.