4.7.2 wiring in the control panel
Principal: production of Chlorine by the cell must be slaved to operation of the filtration pump and circulation
of water through the flow sensor.
Horloge
Disjoncteur magnéto-
thermique pompe
Contacteur*
230 V ~
Bornier alimenta
ti
on
c
offre
t EES
Auto
Disjoncteur, porte-
fusible, ou sec
ti
onneur
Circuit breaker, fuse housing or
switch
EES panel power supply terminal
Magnetotheral circuit breaker, pump
Switch*
Timer
N/LN1 = permanent neutral
LN2 = permanent live (panel and acid dosing pump)
LD2 = slaved live (cell)
*Nota bene: to avoid electrical disturbances when the pump starts and stops, the EES power cables
should not be in contact with those of the filtration pump: use a contactor with 4 power inputs/ outputs as
illustrated in the diagram, or failing this a contactor with 2 power inputs/ outputs for the pump and a relay
for the EES, both slaved to the filtration timer.
The power rating of the panels are as follows:
Panels for pools up to 80 m3 = 0.6 A
Panels for pools up to 150 m3 = 1.2 A
To connect the control panel to the contactor and the contactor to the mains, we recommend that you use
cables with a strand cross section of 1.5 mm
2
. If the cable is very long, use one with a strand cross section
of 2.5 mm
2
.