Turn the top part of the saddle clamp overand make sure the o-ring is in position. place the 2 sections of the
clamp over the hole you just drilled.
Insert the two screws through the saddle clamp holes and tighten them using a13 mm wrench.
•
Wrap the threads of the saddle clamp adapter (½ to ⅜) with Teflon tape and insert it into the saddle clamp.
Wrap the check valve threading with Teflon tape andinsert it into the adapter.
•
Cut the tube supplied to the required length - this will become the injection tube. Attach one end to the outlet
of the acid pump (right side) and the other end to the check valve.
•
Note the arrows visable on the transparent cover of the acid pump, these indicate the suction and injection
direction of the acid.