background image

2019/08 - Indice de révision : D - Code : 29650

TRAITEMENT DE L'EAU

59/72

 

!

IMPORTANT

 

Even in Turbo mode, the device will not run with an output of 100% if the salt concentration 

in the water is too low. It will run at its highest possible output for the current  concentration of salt in 

the water. 

8.5 

Cover mode

This mode concerns pools equipped with a cover and a system that detects when the cover is deployed 

over the pool and closes a dry contact.  

This  is  mainly  useful  for  pools  fitted  with  the  EES  model  because  this  model  does  not  regulate  the 

concentration of Chlorine in the water but rather produces Chlorine for as long as the filtration cycle is 

running. While the cover is deployed over the pool, the free Chlorine is protected from destruction by UV 

radiation and is not being consumed by pollution introduced by bathers, therefore there is a risk that it will 

accumulate in the water while filtration is running. 

The two wires of the dry contact should be connected to the COVER terminal in the control panel (see 

paragraph 4), and the contact should close when the cover is deployed over the pool.  
While the cover is deployed, the message MODE AUX is displayed on the panel's LCD screen, and the 

production of Chlorine is decreased to 20% by default. 

The value by which Chlorine production is decreased while the pool is covered may be modified by the 

user using the arrow keys 

 and  ▲.

The new value will be saved automatically, this will then be the Chlorine output in Cover mode until the 

value is modified again. 

8.6 

Descaling the cell by injecting acid using the acid dosing pump 

Reminder: the acid dosing pump is an integral part of EES Pro, and is available as an option for EES.
The automatic electrode polarity switching system helps slow, and evenly distributed deposition of scale 

on the electrodes in the cell (see paragraph 1 for the explanations).
Nevertheless, and even if the concentration of calcium dissolved in the water is within allowed limits, there 

is a risk that this phenomenon will occur.
The scaling phenomenon may be counteracted by programming the injection of small quantities of acid 

(approx 70 cm3) into the cell using the acid dosing peristaltic pump while filtration is stopped (Stand-by 

mode). The acid injection frequency is set as follows:

• 

stop filtration

• 

press the  

    button to enter CELL CLEANING – AUTO mode

• 

choose an injection frequency (LVL) between 0 and 9 using the arrow keys ▼and ▲ according to the 

following table:

LVL

0

1

2

3

4

5

6

7

8

9

Min. filtration 

duration 

(hours) prior 

to injection

No 

injection

54

48

42

36

30

24

18

12

6

To cancel periodic injections of acid, set the level LVL to 0.  

Содержание EES

Страница 1: ...9 08 Indice de r vision D Code 29650 TRAITEMENT DE L EAU 37 72 INSTALLATION AND OPERATING INSTRUCTIONS to be read carefully and kept for future reference EES ET ESS PRO Electrolysers FR PAGE 1 EN PAGE...

Страница 2: ...tion 46 4 5 3 Procedure 47 4 5 4 When starting up for the first time 49 4 6 Installing the sensors 49 4 6 1 The REDOX sensor 49 4 6 2 pH sensor 50 4 7 Installing the electrical control panel 50 4 7 1...

Страница 3: ...gh and low ph and redox alarms EES Pro only 63 9 8 1 pH HIGH 63 9 8 2 PH LOW 64 9 8 3 ORP HIGH 64 9 8 4 ORP LOW 64 9 9 Ph or redox sensor faults EES Pro only 64 9 10 pH Redox circuit board fault EES P...

Страница 4: ...n which it is mounted These parameters will need to be measured regularly and the pH will need to be adjusted when necessary With the acid dosing pump option installed EES can inject acid to lower the...

Страница 5: ...t When handling acid and during interventions on the pump or its tubing protective glasses and clothing should be worn to protect against splashes In the event of contact with the skin flush the area...

Страница 6: ...EES Pro Electrical control panel 1 The panels of all models have the same outer appearance and the same dimensions Nevertheless the electrical spcifications functional specifications and the internal...

Страница 7: ...nject acid into the hydraulic circuit The acid dosing pump kit includes 2 saddles 50 63mm 3 8 to 1 2 adaptor a check valve valve internal replacement tube 2 x 3m polyethylene tube foot filter and weig...

Страница 8: ...remains in the cell In some configurations this will require installation of a check valve The flow sensor should be positioned such that the acid used to descale the cell will not touch it A check v...

Страница 9: ...d air Pr cautions vis vis des sondes Les parties immerg es des sondes doivent toujours rester immerg es eau de piscine ou du robinet m me hors fonction ne doivent jamais tre touch es avec les doigts n...

Страница 10: ...acid pump and saddle clamp 2 Chlorinator Cell 3 Tee with pH and ORP sensors 4 Flow switch Tee 4 5 2 Horizontal installation 1 Dosing acid pump and saddle clamp 2 Chlorinator Cell 3 Tee with pH and OR...

Страница 11: ...re you wish to install the acid pump on the wall Check that the all components electrical wiring tubes etc reach their position Drill and attach the acid pump s clip to the wall and hang the pump on i...

Страница 12: ...mm wrench Wrap the threads of the saddle clamp adapter to with Teflon tape and insert it into the saddle clamp Wrap the check valve threading with Teflon tape andinsert it into the adapter Cut the tub...

Страница 13: ...ump in MANUAL mode for a few minutes Make sure the red light on the pump is energised that it is running and that acid is being sucked from the acid container and expelled through the injection tube 4...

Страница 14: ...end of the sensor into the union until the end of the sensor is located in the centre of the pipe through which the water is flowing Screw the nut firmly onto the union and check that the sensor canno...

Страница 15: ...5 m tres mais dans tous les cas plus de 2 m tres du plan d eau sous r serve que son c ble d alimentation soit directement reli un dispositif di rentiel r siduel d clenchant 30 mA exigences norme NF C...

Страница 16: ...ory with acid dosing LN2 Live slaved to filtration Cover panel dry contact EES output is unchanged is no voltage is detected at the contact Flow switch Water T C sensor Cell pole Cell pole N Dosing pu...

Страница 17: ...panel and acid dosing pump LD2 slaved live cell Nota bene to avoid electrical disturbances when the pump starts and stops the EES power cables should not be in contact with those of the filtration pu...

Страница 18: ...buffer tank if the pool has an overflow feature and the initial salt concentration measured beforehand USE THE FOLLOWING TABLE 0 500 1000 1500 2000 2500 3000 3500 4500 10 40 35 30 25 20 15 10 5 0 20 8...

Страница 19: ...e message OFF is displayed on the LCD screen Press the ON OFF button 7 If the flow of water past the flow sensor is adequate 5 m3 h the message ON EES or AUTO EES Pro indicating that production of Chl...

Страница 20: ...he EES models only the chlorine output can be adjusted manually by the user by pressing the two arrow keys and This setting will be saved to memory for when the device is started in the future even if...

Страница 21: ...nd maintain it at this temperature if the pool is not equipped with a heating system simply wait until the water naturally reaches the lowest temperature at which bathers will use the pool Next adjust...

Страница 22: ...to switch to Turbo mode the word Turbo blinks at the bottom of the output scale The Turbo mode duration is set to 12 hours in the factory this setting is displayed on screen Successive presses on the...

Страница 23: ...ion of Chlorine is decreased to 20 by default The value by which Chlorine production is decreased while the pool is covered may be modified by the user using the arrow keys and The new value will be s...

Страница 24: ...n EES the cell must be removed from the hydraulic circuit for descaling 8 7 Punctual or periodic reduction of the ph by the acid dosing pump This function concerns EES Pro and also EES if the acid dos...

Страница 25: ...f salt In the event of a low salt warning check that the electrodes are clean and check the salt concentration with a suitable tester in case of doubt A faulty temperature sensor could also cause a lo...

Страница 26: ...along with other indicators if the salt concentration is too low as described previously 9 3 Flow rate too low The message NO FLOW and the icon appear indicating that there is either no flow or insuff...

Страница 27: ...isplayed at the bottom of the LCD screen Cut power to the electrical control panel open the lid of the connection terminal compartment check the condition of the connector contacts the two wires comin...

Страница 28: ...for the Chlorine concentration to fall and to see if the phenomenon reoccurs 9 8 4 ORP LOW ORP LOW this message is displayed when the value measured by the Redox sensor is less than 525 mV If no previ...

Страница 29: ...agitate them Rinse the sensors thoroughly after degreasing After being descaled and degreased the sensors should be recalibrated see the next paragraph and the correspondence between the Redox potent...

Страница 30: ...the filtration pump off ST BY mode close the valves of the by pass loop on which the tee housing the sensors is mounted place a bucket under the tee to collect any water Remove the pH and the Redox s...

Страница 31: ...the tube until it is completely out Note It is advisable to flush the pump with running tap water in order to dilute any remaining acid which may have spilled from the tube Disconnect both ends of the...

Страница 32: ...or 10 Hydrochloric acid into the cell Wait until the scale is completely dissolved stops frothing If scale is still present empty the cell and repeat the procedure with vinegar or acid Rinse the cell...

Страница 33: ...erizing chemicals are added to the water to prevent the growth of algae andfiltration is run every day Filtration must notably be run while the ambient temperature in the plant room where the material...

Страница 34: ...is less than 10 h day The salt concentration is barely within range Measure the salt concentration and if necessary adjust it so that it is between 4 5 and 5 0 g l Scale is starting to build up on th...

Страница 35: ...l remove the lid covering the panel connection terminals and tighten the power cable connections The fuse protecting the main circuit board has blown Contact the after sales service for inspection and...

Страница 36: ...2019 08 Indice de r vision D Code 29650 TRAITEMENT DE L EAU 72 72 S A au capital de 7 000 000 R C S Rennes B 333263846000 37...

Отзывы: