background image

OWNER’S MANUAL

Swimming Pool Pump

READ THIS MANUAL CAREFULLY

BEFORE USING THE SPECK PUMP

SECTION 1 IMPORTANT SAFETY INSTRUCTIONS

When  installing  and  using  this  electrical  equipment,

basic safety precautions should always be followed:

READ  AND  FOLLOW

ALL INSTRUCTIONS.

WARNING

-

To  reduce  the  risk  of  injury,  do  not 

permit children to use this equipment.
(For cord - and plug - connected units)

WARNING

-

Risk of Electric Shock.  Connect only 

to  a  grounding  type  receptacle  protected  by  a 

ground-fault  circuit-interrupter  (GFCI).  Contact  a 

qualified  electrician  if  you  cannot  verify  that  the 

receptacle is protected by a GFCI.
(For cord - and plug - connected units)

WARNING

-

Do  not  bury  cord.    Locate  cord  to 

minimize abuse from lawn mowers, hedge trimmers,

and other equipment.
(For cord - and plug - connected units)

WARNING

-

To  reduce  the  risk  of  electric  shock,

replace damaged cord immediately.
(For cord - and plug - connected units)

WARNING

-

To reduce the risk of electric shock, do

not use extension cord to connect unit to electric supply;

provide a properly located outlet.
(For  swimming  pool  pumps  with  a  minimum  25-foot

(7.6-m) cord)

NOTE:

All wiring should be done by a qualified electrician in accordance with the National Electrical Code and all Local Codes.

NOTE:

Before installation, inspect all equipment, plumbing and wiring for damage that may have occurred during shipment.

The shipping container has been specifically designed to prevent damage, however, any indications of damage should be

carefully noted on the delivery ticket and a claim needs to be filed with the carrier.

All pumps are water tested on a test stand to ensure that they meet specification.

CAUTION

-

This pump is for use with storable pools

only.  Do not use with permanently installed pools.  A

storable pool is constructed so that it may be readily

disassembled  for  storage  and  reassembled  to  its 

original  integrity.    A permanently  installed  pool  is 

constructed in or on the ground or in a building such

that it cannot be readily disassembled for storage.
(For  swimming  pool  pumps  with  or  without  a 

maximum 3 foot (0.91 -m) cord)

CAUTION

-

This pump is for use with permanently

installed  pools  and  may  also  be  used  with  hot  tubs

and  spas  if  so  marked.    Do  not  use  with  storable

pools.  A permanently installed pool is constructed in

or on the ground or in a building such that it cannot be

readily disassembled for storage.  A storable pool is

constructed so that it may be readily disassembled for

storage and reassembled to its original integrity.

TO REDUCE RISK OF ELECTRICAL SHOCK,

connect ground wires to grounding screw located in the

motor.  Use no smaller than a #1 2 AWG (3.3mm2) wire.

TO REDUCE RISK OF ELECTRICAL SHOCK,

a bonding connector is provided for bonding to metal

water pipes, metal rails, or other metal within 5 feet of

the swimming pool.  All local points should be bonded

with a #8 AWG (8.4mm2) wire.

NOTE:

To  installer  and/or  operator  of  the  Speck

Swimming Pool Pump; the manufacturer’s warranty will

be void if the pump is improperly installed and/or operated.

READ INSTRUCTIONS CAREFULLY.

SAVE THESE INSTRUCTIONS!

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

SECTION 2 WINTERIZING

In  areas  subject  to  freezing  winter  temperatures, 

protect by removing drain plugs.  Do not replace plug.

Store plug in strainer basket for winter.

An alternative is to remove the pump and motor from

plumbing and store indoors in a warm and dry location.

Содержание Swimming Pool Pump

Страница 1: ...sted on a test stand to ensure that they meet specification CAUTION This pump is for use with storable pools only Do not use with permanently installed pools A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original integrity A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disass...

Страница 2: ...el 93 2999999926 BONDING As required by National Electrical Code Article 680 22 the pump motor must be electrically bonded to the pool structure reinforced bars etc by a solid copper conductor not smaller than 8 AWG via the external copper bonding lug on the pump motor GROUNDING Permanently ground the pump motor using a conductor of appropriate size Connect to the 10 green headed ground screw prov...

Страница 3: ...rays Do not tighten cover or enclose motor a Suction air leak b No water in pump c Closed valves or blocked lines d Low voltage to motor a No power to motor b Pump jammed a Dirty filter b Dirty skimmer basket c Suction air leak d Closed valves or blocked lines a Bad bearings a Low voltage b Installed in direct sun c Poor ventilation 1 Pump will not prime 2 Motor does not turn 3 Low flow 4 Noisy op...

Страница 4: ...der shall be to replace or repair any defective pump or motor The manufacturer reserves the absolute right to determine whether any defective pump or motor should be replaced or repaired Any customer who wishes to make a claim under this Limited Warranty shall notify the manufacturer of such claim by telephone or by mail After the customer has been authorized to return a defective pump or motor th...

Отзывы: