background image

Flockmatic Vario

 

Version 2.1 

GB 

 

Operating manual  

 

 

 

Flocculant dosing pump

 

 

 

 
 

 
 
 
 

 

 

Содержание Flockmatic Vario

Страница 1: ...Flockmatic Vario Version 2 1 GB Operating manual Flocculant dosing pump ...

Страница 2: ......

Страница 3: ...1 Safety instructions for installation and mintenance tasks 7 4 2 Mounting 7 4 3 Electrical connection 7 4 4 Replacing the device fuse 7 4 5 Installation in the circulation system 8 4 6 Maintenance 8 4 6 1 14 day maintenance 8 4 6 2 Yearly maintenance 8 4 6 3 Cleaning 8 4 6 4 Hose replacement Flockmatic Vario 8 4 7 Winter care 9 4 8 Decommissioning 9 5 TECHNICAL DATA 9 6 SPARE PARTS 9 ...

Страница 4: ...lification of personnel Possible consequence Death or severe injury significant damage to material assets The system owner must ensure compliance with the required qualifications All activities must only be carried out by personnel who are qualified to perform such activities Access to the system must be prevented for inadequately qualified personnel IMPORTANT NOTE Compliance with the applicable a...

Страница 5: ...states Status Description Off The display is switched off the pump does not display the filling level of the canister for flocculent is not evaluated and no input can be made The green LED flashes at intervals of approx 2 sec Activate the button for approximately 1 second to switch on the device the device is in operating status Off On The green LED flashes briefly at intervals of approx 2 sec the...

Страница 6: ...city is set in accordance with the circulation pump used Available languages The device can be configured for multiple languages Acoustic signal The acoustic signal that is triggered when the filling level of the canister for flocculent is low can be activated or deactivated The visual alarm signal will always be output regardless of this setting Output of the alarm via the PoolManager Analyt only...

Страница 7: ...r heat conducting pipes or systems Direct sunlight thermal radiation the effects of frost and moisture must be avoided Ensure adequate aeration Ensure that measures are in place in the event of a leak in the pump or the dosing hoses e g defined discharge collecting container The base plate can be used as a drilling template by holding it at the intended location and marking the location of the bor...

Страница 8: ...is only use a little water if necessary IMPORTANT NOTE Do not use aggressive cleaners 4 6 4 Hose replacement Flockmatic Vario NOTE Never grease the hose NOTE Only use original spare pump hoses DANGER Danger due to chemicals When pulling off the pump hose corrosive product residues can escape Possible consequence Serious health impairment acid burns and damage to material assets Always empty the pu...

Страница 9: ...s with water and empty them completely After the winter season all components must be examined to determine that they are functional All dismounted parts must be remounted at their intended position Check the settings of the Flockmatic Vario 4 8 Decommissioning If the device will be disposed of after its service life it must be flushed out and the water drained The device has been manufactured in ...

Отзывы: