Overview 

The Flockmatic Vario is a high quality peristaltic pump for 
dosing of liquid flocculants in the circulation circuit of a 

swimming pool.  
The swimming pool must be equipped with an adequately 
dimensioned sand filter system. 

3

 

Operation 

The Flockmatic Vario is operated via the two-row display with 2 
x 16 characters and the membrane pushbuttons. 

3.1

 

Button functions 

 

Button 

 

Function 

 

Switches from the basic view to the menu 
structure. 

 

-

 

Switches  from  the  menu  structure  back 

to basic view. 

-

 

Switches  from  one  menu  item  to  the 

next higher menu item. 

-

 

When  exiting  an  input  menu  the 
selected settings are not applied. 

 

-

 

Opens the input menu of a menu item. 

-

 

Confirms  the  changed  settings  in  an 
input menu. 

    

and

 

 

-

 

Navigates  between  the  individual  menu 
items. 

-

 

Changes the setting values in the input 

menu. 

 

3.2

 

Operating states 

 

Status 

 

Description 

Off 

The display is switched off, the pump does 
not display, the filling level of the canister 
for flocculent is not evaluated, and no 
input can be made. The green LED 

 

flashes at intervals of approx. 2 sec. 
Activate the 

 button for approximately 

1 second to switch on the device; the 

device is in operating status Off. 

On 

The green LED 

 flashes briefly at 

intervals of approx. 2 sec, the display is 
switched on and inputs can be made. 
Briefly activate the 

 button to switch 

the device to automatic mode. 

Dosing 

The green LED 

 is illuminated 

continuously. The display is switched on 
and inputs can be made. 

If the filling level of the canister for 
flocculent is low, an alarm will be 
triggered. 

Fast vacuum function: 

With this function the air can be quickly 

removed from the suction and pressure 
hose. For this, the dosing pump is 
switched on manually with the 

 

button for approximately one minute with 

full capacity. Subsequent pushing of the 

 button switches off the pump as 

needed before one minute elapses. 

 

 

Содержание Flockmatic Vario

Страница 1: ...Flockmatic Vario Version 2 1 GB Operating manual Flocculant dosing pump ...

Страница 2: ......

Страница 3: ...1 Safety instructions for installation and mintenance tasks 7 4 2 Mounting 7 4 3 Electrical connection 7 4 4 Replacing the device fuse 7 4 5 Installation in the circulation system 8 4 6 Maintenance 8 4 6 1 14 day maintenance 8 4 6 2 Yearly maintenance 8 4 6 3 Cleaning 8 4 6 4 Hose replacement Flockmatic Vario 8 4 7 Winter care 9 4 8 Decommissioning 9 5 TECHNICAL DATA 9 6 SPARE PARTS 9 ...

Страница 4: ...lification of personnel Possible consequence Death or severe injury significant damage to material assets The system owner must ensure compliance with the required qualifications All activities must only be carried out by personnel who are qualified to perform such activities Access to the system must be prevented for inadequately qualified personnel IMPORTANT NOTE Compliance with the applicable a...

Страница 5: ...states Status Description Off The display is switched off the pump does not display the filling level of the canister for flocculent is not evaluated and no input can be made The green LED flashes at intervals of approx 2 sec Activate the button for approximately 1 second to switch on the device the device is in operating status Off On The green LED flashes briefly at intervals of approx 2 sec the...

Страница 6: ...city is set in accordance with the circulation pump used Available languages The device can be configured for multiple languages Acoustic signal The acoustic signal that is triggered when the filling level of the canister for flocculent is low can be activated or deactivated The visual alarm signal will always be output regardless of this setting Output of the alarm via the PoolManager Analyt only...

Страница 7: ...r heat conducting pipes or systems Direct sunlight thermal radiation the effects of frost and moisture must be avoided Ensure adequate aeration Ensure that measures are in place in the event of a leak in the pump or the dosing hoses e g defined discharge collecting container The base plate can be used as a drilling template by holding it at the intended location and marking the location of the bor...

Страница 8: ...is only use a little water if necessary IMPORTANT NOTE Do not use aggressive cleaners 4 6 4 Hose replacement Flockmatic Vario NOTE Never grease the hose NOTE Only use original spare pump hoses DANGER Danger due to chemicals When pulling off the pump hose corrosive product residues can escape Possible consequence Serious health impairment acid burns and damage to material assets Always empty the pu...

Страница 9: ...s with water and empty them completely After the winter season all components must be examined to determine that they are functional All dismounted parts must be remounted at their intended position Check the settings of the Flockmatic Vario 4 8 Decommissioning If the device will be disposed of after its service life it must be flushed out and the water drained The device has been manufactured in ...