background image

4.5

 

Installation in the circulation system 

Install the Flockmatic Vario in the circulation system as follows. 
 

 

1 Flockmatic Vario 
2 Quickflock fluid 
3 Heat exchanger  

4 Filter 
5 Injection after the circulation pump 
6 Filter pump 

7 Injection before circulation pump 
  (recommended if counter  pressure is higher than 0.8 bar) 

Connect the suction hose (connection to the canister) on the 

left connection of the pump, connect the pressure hose 
(connection to the injection nozzle) on the right connection of 

the pump. 

 

 

IMPORTANT NOTE 

For all hose and mounting connections, ensure 
that these connections do not leak. 

Liability is excluded if there are leaks! 

4.6

 

Maintenance 

Some parts of the Flockmatic Vario are subject to wear due to 

chemical and mechanical stress. Thus regular inspection is 
required for safe, long-term operation. Regular preventive 
maintenance of the system protects against unscheduled 

interruptions of operation. 

4.6.1

 

14-day maintenance 

 

Visual inspection of all dosing lines and the dosing hose 

for leaks, replace if necessary 

4.6.2

 

Yearly maintenance 

 

Visual inspection of all dosing lines, replace if necessary 

 

Replacement of the hose of the dosing pump 

4.6.3

 

Cleaning 

Clean the surfaces of the device with a soft lint-free cloth as 

needed. To do this only use a little water, if necessary 

 

 

IMPORTANT NOTE 

Do not use aggressive cleaners 

 

4.6.4

 

Hose replacement Flockmatic Vario 

 

 

NOTE 

Never grease the hose! 

 

 

NOTE 

Only use original spare pump hoses! 

 

 

DANGER! 
Danger due to chemicals 

When pulling off the pump hose, corrosive 
product residues can escape. 

Possible consequence: Serious health 

impairment (acid burns) and damage to 
material assets 

 

Always empty the pump hose and supply 
lines first. 

 

If necessary wear protective goggles and 
protective gloves and protect the 

surroundings against escaping product 
residues with a cloth. 

 

 

DANGER! 
Danger due to rotating parts  

The rotor of the dosing pump can start-up 
abruptly. 

Possible consequence: Danger of crushing 

for fingers! 

Ensure that the dosing pump remains 
disconnected from the operating voltage while 

replacing the hose (unplug the mains plug)! 

 

The hose of the dosing pump is replaced without dismounting 
the rotor. 

 

 

Remove the emptied suction and pressure hoses from the 
hose holder. To do this open the blue clamping screws. 

 

Take the transparent cover 1 off of the pump. 

 

Take off the blue cover 2 of the rotor. 

 

Turn rotor 3 in such a manner that the flat side points to 

the left and is vertical. 

 

Pull the hose holder 4 out of its holder and lift it on the left 

side. 

 

Now  turn  the  rotor  3  clockwise  and  follow  with  the  hose 

lifted until it is completely free. 

 

Proceed in the reverse sequence for mounting. 

 
The hose only, or the hose together with the hose holder can 

be replaced.  

Содержание Flockmatic Vario

Страница 1: ...Flockmatic Vario Version 2 1 GB Operating manual Flocculant dosing pump ...

Страница 2: ......

Страница 3: ...1 Safety instructions for installation and mintenance tasks 7 4 2 Mounting 7 4 3 Electrical connection 7 4 4 Replacing the device fuse 7 4 5 Installation in the circulation system 8 4 6 Maintenance 8 4 6 1 14 day maintenance 8 4 6 2 Yearly maintenance 8 4 6 3 Cleaning 8 4 6 4 Hose replacement Flockmatic Vario 8 4 7 Winter care 9 4 8 Decommissioning 9 5 TECHNICAL DATA 9 6 SPARE PARTS 9 ...

Страница 4: ...lification of personnel Possible consequence Death or severe injury significant damage to material assets The system owner must ensure compliance with the required qualifications All activities must only be carried out by personnel who are qualified to perform such activities Access to the system must be prevented for inadequately qualified personnel IMPORTANT NOTE Compliance with the applicable a...

Страница 5: ...states Status Description Off The display is switched off the pump does not display the filling level of the canister for flocculent is not evaluated and no input can be made The green LED flashes at intervals of approx 2 sec Activate the button for approximately 1 second to switch on the device the device is in operating status Off On The green LED flashes briefly at intervals of approx 2 sec the...

Страница 6: ...city is set in accordance with the circulation pump used Available languages The device can be configured for multiple languages Acoustic signal The acoustic signal that is triggered when the filling level of the canister for flocculent is low can be activated or deactivated The visual alarm signal will always be output regardless of this setting Output of the alarm via the PoolManager Analyt only...

Страница 7: ...r heat conducting pipes or systems Direct sunlight thermal radiation the effects of frost and moisture must be avoided Ensure adequate aeration Ensure that measures are in place in the event of a leak in the pump or the dosing hoses e g defined discharge collecting container The base plate can be used as a drilling template by holding it at the intended location and marking the location of the bor...

Страница 8: ...is only use a little water if necessary IMPORTANT NOTE Do not use aggressive cleaners 4 6 4 Hose replacement Flockmatic Vario NOTE Never grease the hose NOTE Only use original spare pump hoses DANGER Danger due to chemicals When pulling off the pump hose corrosive product residues can escape Possible consequence Serious health impairment acid burns and damage to material assets Always empty the pu...

Страница 9: ...s with water and empty them completely After the winter season all components must be examined to determine that they are functional All dismounted parts must be remounted at their intended position Check the settings of the Flockmatic Vario 4 8 Decommissioning If the device will be disposed of after its service life it must be flushed out and the water drained The device has been manufactured in ...

Отзывы: