Burnham 4FHL-107A Скачать руководство пользователя страница 28

28

LIMITED WARRANTY

LIMITED WARRANTY

Subject to the terms and conditions herein, Seller warrants 

to the original owner at the original installation site that 

products manufactured by Seller (“Products”) comply, 

at the time of manufacture, with recognized hydronics 

industry regulatory agency standards and requirements 

therein effect and will be free from defects in materials and 

workmanship for a period of 12 months after the date of 

start-up or 18 months after the date of shipment, whichever 

shall be less (the “Warranty Period”)

REMEDY

A.   The sole remedy for breach of this warranty is    

 

expressly limited to the repair or replacement of any  

 

part found to be defective under conditions of normal  

 

use within the Warranty Period. Installation is not   

 included.

B.   Warranty  The owner must notify the original installer  

 

of the Product and Seller (Attention: Burnham    

 

Commercial, PO Box 3939, Lancaster, PA 17604) in  

 

writing, within the Warranty Period, providing a detailed  

 

description of all claimed defects. Transportation to a  

 

factory or other designated facility for repairs of any  

 

products or items alleged defective shall, in all events,  

 

be the responsibility and at the cost of the owner.

EXCLUSIONS

Seller shall have no liability for:

A.   Incidental, special or consequential damages, such as  

 

loss of the use of products, facilities or production,  

 

inconvenience, loss of time or labor expense involved  

 

in the repairing or replacing of the alleged defective  

 Product.

B.   The performance of any Product under conditions  

 

varying materially from those under such Products is  

 

usually tested under industry standards as of the   

 

shipment time.

C.   Any damage to the Product due to abrasion, erosion,  

 

corrosion, deterioration, abnormal temperatures or the  

 

influence of foreign matter or energy.

D.   The design or operation of owner’s plant or equipment  

 

or of any facility or system of which any Product may  

 

be made a part.

E.   The suitability of any Product for any particular    

 application.

F.   Any failure resulting from misuse, modification, not  

 

authorized by Seller in writing, improper installation or  

 

lack of proper maintenance.

G.   Equipment furnished by the owner, either mounted or  

 

unmounted, or when contracted for by owner to be  

 

installed or handled. 

 

Seller’s liability under this warranty shall not in any case 

exceed the amount paid for the Product found defective.

THIRD-PARTY WARRANTIES

For goods or components not manufactured by Seller, the 

warranty obligations of Seller shall, in all respects, conform 

and be limited to the warranty actually extended to Seller by 

its vendors.

SEVERABILITY

To the extent that any provisions of this warranty would be 

void or prohibited under applicable law, such provisions 

shall be limited in effect to the minimum extent necessary to 

render the remaining provisions hereof enforceable. 

NO OTHER WARRANTIES

Seller makes no implied warranty of merchantability or 

fitness for a particular purpose, or other warranties with 

respect to any products or services except as expressly set 

forth in this limited warranty.

Form No. 81460434 - 2/17

Printed in the U.S.A.

Lancaster, PA  17601

Phone: 888-791-3790

www.burnhamcommercial.com 

Commercial Boilers

Содержание 4FHL-107A

Страница 1: ...hnician BEFORE installing read all instructions in this manual and all other information shipped with the boiler Post all instructions and manuals near the boiler for reference by service personnel Pe...

Страница 2: ...es having jurisdiction should be consulted before installations are made C All wiring on boilers installed in Canada shall be made in accordance with the Canadian Electrical Code and or Local Regulati...

Страница 3: ...ne Burner boiler systems produce steam or hot water in a pressurized vessel by mixing extremely flammable gaseous liquid or solid fuels with air to produce combustion and very hot products of combusti...

Страница 4: ...e s ret sont absents ou install s l aide de cavaliers Ne pas faire fonctionner si une commande un interrupteur un composant ou un dispositif est entr en contact avec de l eau Improper installation adj...

Страница 5: ...e combustible contiennent de l alumine de la silice des m taux lourds du monoxyde de carbone des oxydes d azote des ald hydes ou d autres substances toxiques ou dangereuses pouvant causer la mort ou d...

Страница 6: ...ted piping electrical and control systems used and maintained in the boiler room Le terme syst me de br leur chaudi re utilis dans ce manuel signifie tout quipement m canique ou lectrique y compris la...

Страница 7: ...esting Controls 16 17 Initial Cleaning Steam Boilers 17 Initial Cleaning Water Boilers 17 18 Water Boiler Operation 18 Boiler Water Treatment 18 pH or Alkalinity Test 18 Warnings about Frequent Water...

Страница 8: ...ombustion efficiency of over 80 This manual gives the necessary information for the proper installation operation maintenance and service of units For special installation problems contact Burnham Com...

Страница 9: ...um capacity and will light off and have stable and consistent combustion On installations where a natural draft stack is used causing high breeching drafts the boiler locking blade damper on boilers e...

Страница 10: ...altitude installations above 1 000 ft An adjustment of 3 5 per 1 000 ft of elevation is recommended 6 LOCATION OF ASME STAMPING DATA The ASME stamping data is located as follows 1 Series 4FH Sizes 63...

Страница 11: ...the boiler warms up If formation of condensate persists the low limit should be adjusted upward until condensate no longer forms Water boilers and low pressure steam boilers must have a set LFH at 12...

Страница 12: ...es in the boiler metal These stresses can cause damage to the boiler by loosening tubes or in more severe instances can crack tube sheet ligaments furnaces or waterlegs B If temperature differentials...

Страница 13: ...MANUAL 9 RELIEF VALVES Boiler relief valves are normally shipped loose and have been properly sized for your boiler The aggregate capacity of the relief valves as stamped on the valve rating plates mu...

Страница 14: ...14 FIGURE 4 TS 71 130 D INSTALLATION INSTRUCTIONS FIGURE 3 TS 71 176 B...

Страница 15: ...15 TS 71 131 D FIGURE 5 TS 3 101 4 INSTALLATION INSTRUCTIONS FIGURE 6...

Страница 16: ...control Avant que l installation de la chaudi re soit consid r e comme termin e v rifier le fonctionnement de ses dispositifs de contr le en particulier les interrupteurs bas niveau d eau et le contr...

Страница 17: ...afety relief valve using extreme care to avoid damaging it A Check Operating Control Raise and lower operating control setting as required to start and stop burner B Warning Check High Limit Control J...

Страница 18: ...WATER TREATMENT Boiler water treatment will help maximize the effectiveness and prolong the life of pressure vessels The general objectives of boiler water treatment are A Remove corrosive gases from...

Страница 19: ...chaudi re par l oxyg ne provoque la corrosion des composants en fer et en acier et peut mener une d faillance La garantie standard de Burnham ne couvre pas les probl mes caus s par la contamination de...

Страница 20: ...emperature to increase even if the gauge pressure is 0 It is better to allow the entire system to cool gradually never force cool the boiler as damage can also be inflicted due to thermal shock G When...

Страница 21: ...rbulator replacement is from the front smokebox Turbulators should be installed and removed from the front of the boiler only Series 4FH All 4FH Series boilers come equipped with turbulators in all th...

Страница 22: ...to solder joints on bellows and float when this type of control is used Check the float for evidence of collapse and check mercury bulb where applicable for mercury separation or discoloration DO NOT...

Страница 23: ...at the end of heating season Drain off boiler water until it runs clear while holding the boiler temperature between 180 and 200 F Then refill to top of gauge glass B Water Boilers Since a water boile...

Страница 24: ...ion Safety Controls Flame Failure Weekly Operator If flame display installed read and log for both pilot and main flames notify service organization if readings are very high very low or fluctuating r...

Страница 25: ...ition Interlock Annually Service Technician Refer to burner instructions Low Fire Start Interlock Annually Service Technician Refer to burner instructions Automatic Changeover At Least Annually Servic...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...Product under conditions varying materially from those under such Products is usually tested under industry standards as of the shipment time C Any damage to the Product due to abrasion erosion corro...

Отзывы: