54
English
SE58
L
The batching process automatically stops the valve when the batching quantity reaches the set value. If the
delivered volume doesn’t match to the required one, it’s necessary to notice empirically the value to set. In this
way It is possible to compensate any “delays” in the process after the stop signal.
Delivered volume
START
STOP
START
STOP
Closing valve
Time
Closing valve
Time
EXAMPLE WITH DELIVERED VOLUME = 1 dm³
Batch quantity
Delivered volume
Batch quantity
BATCH VALUE NOT ADJUSTED
VALUE AJDUSTED TO COMPENSATE
THE BATCH OVER VALUE (0,3 dm³)
1 dm³
0.3 dm³
0.7 dm³
0.3 dm³