SE58
L
The SE58 L can show a 5 digits display for flow rate units; this mean the maximum flow rate value that can be
represented on the display is 99999 (no matter the positioning of the decimal point). The minimum is 0.0025.
The representable measure unit depends on sensor flow rate and diameter; the permitted units are those, that
permits the device full scale value not exceeding 99999.
Example for DN 300, Full scale value: 3m/s:
• PERMITTED:
measure unit (example): l/s (216.00); m3/h (777.60); m3/s (0.2160)
• NOT PERMITTED:
measure unit (example): l/h (777600)
FLOW RATE VISUALIZATION
This symbol appears (red color on the
virtual display) only when the overall noise
is over 2.5% of flow rate.
This
FLAG
becomes active when there is a flow variation (flow rate not stable).
The user has immediate access to the Quick Start menu when the transmitter is powered up by pressing the
Enter key. If access to the quick start menu does not occur, then it could be disabled using the function “9.11”
QUICK START MENU
See programming
functions section
Access to all functions
FLOW RATE ALERT
The
QUICK START MENU
allows to the user an immediate access to some of the most commonly used
functions; through MCP software it is possible to customize this menu to make it suitable for a specific
application.
Содержание B0A1C2B1A4A0
Страница 1: ...Type SE58 L Transmitter Operating Instructions...
Страница 8: ...7 English SE58 L Dimensions 200 114 164 167 114 180 290 195...
Страница 9: ...8 English SE58 L Remote version 142 28 295 120 7 30...
Страница 11: ...10 English SE58 L DIMENSIONS STAINLESS STEEL VERSION Compact Version 171 156 186 146...
Страница 12: ...11 English SE58 L Separate Version 236 40 7 90 241 55...