User Guide
125
www.bull.com
In the example below, the hard disk drive in slot number 2 has been replaced.
The indication "PD Missing from DGx: Slot 2: xxxxx MB" indicates that the
PD (physical drive) installed in slot number 2 was removed.
Figure 76: WebBIOS Top Menu
2.
Select "():1:2" (newly connected HDD) in [Physical Drives].
The Physical Drive properties screen is displayed.
3.
Select "Make Global HSP" or "Make Dedicated HSP" on the lower part of the
screen, and click [Go] on the lower center of the screen.
Figure 77: Physical Drive Properties Screen