Logamatic SC40 - Technical specifications are subject to change without prior notice.
19
Installation (for engineers only)
4
4.4.7
Configuration diagram T5 - solar water heating with preheating stage charge
transfer
Fig. 13
R1
Solar circuit pump 1
R3
Charge transfer pump
S1
Collector temperature sensor FSK
S2
Cylinder 1 bottom temperature sensor
S3
Cylinder 1 top temperature sensor
S4
Cylinder 2 bottom temperature sensor
S7
Flow heat meter WMZ temperature sensor (optional)
S8
Return heat meter temperature sensor (optional)
WMZ
Heat meter (optional)
WMZ
R1
S1
R3
S3
S2
S4
S8
S7
7747006072-08.1 SD
S1 S2 S3 S4 S5 S6 S7 S8
I9
L
N
R1 N1 R2 N2 R3 R3 R4 R4 R5 R5
L3 N3 L4 N4 L5 N5
230V
AC
R3
R1
S1 S2 S3 S4
S7 S8 WMZ