Logamatic SC40 - Technical specifications are subject to change without prior notice.
13
Installation (for engineers only)
4
4.4
Electrical connections
4.4.1
Preparing cable entry
The cables can be fed into the housing from behind (
Æ
Fig. 8, item 4) or from below (
Æ
Fig. 8,
item 3).
V
Maintain IP 20 protection when installing:
– Cut open only the cable entries required.
– Cut open the cable entry only as much as required.
V
To avoid jagged edges, cut out the cable entries with a knife (
Æ
Fig. 8).
V
Secure cables with the appropriate cable grips (
Æ
Fig. 8, item 2). The strain relief clamp can also
be fitted in the reverse position (
Æ
Fig. 8, item 1).
Fig. 8
Feeding in and securing cables
1
Cable grip reversed
2
Cable grip
3
Cable entry from below
4
Cable entry from the rear
5
Fuse, 2.5 A slow (2 off)
Danger:
risk of electric shock.
V
Disconnect the power supply (230 V AC) before opening up the controller.
V
Secure the cable with the cable grip.
7747006072-02.1 SD
2
3
4
1
5
4