Logamatic SC40 - Technical specifications are subject to change without prior notice.
33
Installation (for engineers only)
4
4.4.21
Configuration diagram H11 - heating boost system with East/West aspect func-
tion and 2 cylinders connected via valve and without return boost valve
Fig. 27
R1
Solar circuit pump 1
R2
Solar circuit pump 2
R3
Daily heating pump (optional)
R4
Cylinder selection valve
S1
Collector temperature sensor FSK, field 1
S2
Cylinder 1 bottom temperature sensor
S3
Cylinder 2 top temperature sensor (optional)
S4
Cylinder 2 bottom temperature sensor
S5
Collector temperature sensor FSK, field 2
S6
Cylinder 1 top temperature sensor (optional)
S7
Flow heat meter WMZ temperature sensor (optional)
S8
Return heat meter temperature sensor (optional)
WMZ
Heat meter (optional)
WMZ
5
R1
S2
S3
S8
S7
R4
S4
R2
S1
S5
R3
7747006072-25.1 SD
S6
S1 S2 S3 S4 S5 S6 S7 S8
I9
L
N
R1 N1 R2 N2 R3 R3 R4 R4 R5 R5
L3 N3 L4 N4 L5 N5
230V
AC
R4
R3
R2
R1
S1 S2 S3 S4 S5 S6 S7 S8 WMZ