Logamatic SC40 - Technical specifications are subject to change without prior notice.
27
Installation (for engineers only)
4
4.4.15
Configuration diagram H5 - heating boost system with 2 cylinders connected via
valve
Fig. 21
R1
Solar circuit pump 1
R3
Daily heating pump (optional)
R4
Cylinder selection valve
R5
Return flow boost valve
S1
Collector temperature sensor FSK
S2
Cylinder 1 bottom temperature sensor
S3
Heating return temperature sensor
S4
Cylinder 1 top temperature sensor (optional)
S5
Cylinder 2 bottom temperature sensor
S6
Cylinder 2 top temperature sensor
S7
Flow heat meter WMZ temperature sensor (optional)
S8
Return heat meter temperature sensor (optional)
WMZ
Heat meter (optional)
WMZ
R1
S2
S4
S3
S6
S8
S7
R5
S1
R4
S5
R3
7747006072-14.1 SD
S1 S2 S3 S4 S5 S6 S7 S8
I9
L
N
R1 N1 R2 N2 R3 R3 R4 R4 R5 R5
L3 N3 L4 N4 L5 N5
230V
AC
R4
R3
R5
R1
S1 S2 S3 S4 S5 S6 S7 S8 WMZ