Installation (for engineers only)
Logamatic SC40 - Technical specifications are subject to change without prior notice.
38
4
4.4.26
Configuration diagram S3 - swimming pool with East/West aspect function
Fig. 32
R1
Solar circuit pump 1
R2
Heat exchanger pump
R3
Solar circuit pump 2
R4
Cylinder selection valve
R5
Anti-icing system valve (optional)
S1
Collector temperature sensor FSK, field 1
S2
Cylinder bottom temperature sensor
S3
Swimming pool temperature sensor
S4
Cylinder centre temperature sensor (optional)
S5
Collector temperature sensor FSK, field 2
S6
Temperature sensor for external heat exchanger
S7
Flow heat meter WMZ temperature sensor (optional)
S8
Return heat meter temperature sensor (optional)
WMZ
Heat meter (optional)
WMZ
5
R1
S2
S3
S8
S7
R5
S1
R4
R2
S6
S4
R3
S5
7747006072-32.1 SD
S1 S2 S3 S4 S5 S6 S7 S8
I9
L
N
R1 N1 R2 N2 R3 R3 R4 R4 R5 R5
L3 N3 L4 N4 L5 N5
230V
AC
R4
R3
R5
R2
R1
S1 S2 S3 S4 S5 S6 S7 S8 WMZ