3
Transportation
Logalux PL750/2 S - Changes may be made following technical improvements!
10
3.1.2
Transportation with overhead crane
V
Place the two lifting hooks of the chain into the desig-
nated lifting rings on top of the tank.
V
Hook the crane chain into the lifting chain.
V
Protect the tank from falling and lift the tank to its final
installation location.
V
Lower the tank carefully to the floor; do not drop down
onto the floor!
One can move the tank inside the building also in a hori-
zontal manner due to possible height restrictions.
V
Remove only the tank packaging at the final installation
site.
Fig. 5
Transportation with lifting crane
1
Lifting eyes
3.2
Product Placement
V
Maintain suggested service access dimensions
(
Æ
Fig. 6).
V
Place tank on a level and sufficiently strong floor.
Clearance to wall
Fig. 6
Recommended minimum clearances
(in inch/mm)
1
Solar Combi-tank
2
Boiler
Caution:
Damage due to internal stresses!
V
Place the tank in a frost free room.
V
Use the solar combi-tank ONLY in closed
loop applications.
V
Open expansion tanks can NOT be used
with these solar combi-tanks.
Sufficient overhead space is required for the
removal of the magnesium anode rod as well
as some side clearance.
V
Verify for suitable clearance dimensions by
referencing Tab. 1, page 7 and Fig. 6.
20"/500
>4"/>100
16"/400
1
2
6 720 615 217-08.1RS